Patient-prosthetic aortic valve mismatch (PPM) is a clinical diagnosis in which an aortic prosthetic valve is normal structurally, but hemodynamically functions as aortic stenosis, with higher prosthetic valve gradients than would be expected for that particular valve.1,2 The prosthetic valve functions as designed but hemodynamics are less than ideal compared with a native valve. The predominant hemodynamic consequence of PPM is generation of an abnormally high mean pressure gradient (MPG), which may become evident only during or after exercise. The MPG is related to flow (Q) and prosthetic effective orifice area (EOA) by the following relationship:

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

مقایسه اندازه دریچه آئورت مصنوعی نصب شده با قطر رینگ دریچه آئورت به طریقه اکوکاردیوگرافی دو بعدی بمنظور پیش بینی اندازه دریچه مصنوعی آئورت قبل از عمل جراحی

In recent socio-economic state it is not possible to have different sets of prosthetic cardiac valves available in the operating room before open-heart surgery for valvular replacement. In this study the diameter of the aortic valve ring measured in 2-D echocardiography was compared with the size of the aortic prosthetic valves implanted for the patients with aortic valvular disease. The purpos...

متن کامل

Intermediate TEE

Over 56,000 aortic valves are replaced annually in the United States, making AS the second most common reason for heart surgery, behind only coronary artery disease. The intraoperative echocardiographer plays a part in confirming the diagnosis of AS, quantifying its severity, and ensuring proper prosthetic valve function postoperatively. However, the aortic valve is only one component of the ao...

متن کامل

Prosthesis-patient Mismatch - What Cardiac Anesthesiologists Need to Know?

Prosthesis-patient Mismatch (PPM) is not uncommon with an incidence reported up to 70% after aortic valve (AV) replacement. Severe forms of PPM are less common (up to 20%); PPM can lead to increased short- and long-term morbidity and mortality. It is important to discriminate PPM from other forms of prosthetic valve dysfunction. Sometimes, prosthetic valve degenerative disease may coexist with ...