Non-destructive Dp Analysis of Kraft Paper from Shell-type Power Transformers
نویسندگان
چکیده
Rapid, cost-effective, non-destructive diagnosis of power transformer condition is an increasingly important area of asset management – this includes the need to be able to estimate the aged condition of the coil insulation nondestructively. This is necessary to assess the reliability and potential risks presented by transformers in a particular population as well as gauging the prospective life expectancy of individual transformers. A portable fiber-optic spectroscopic probe system has been developed which can achieve this quickly by determining the degree of polymerization (DP), an indicator of degradation, to an accuracy of 40 DP units in the presence of the insulating oil. The system uses a hand-held optical probe that gathers spectral information which is analysed using dedicated multivariate analysis software. Following calibration and measurement trials in the laboratory, the instrument has been used in the field, to provide DP values based on in-situ measurements of the exposed windings of de-tanked transformers, and can also be used to determine water content. The method is still in development, but already it is highlighting ageing differences between core and shelltype transformers. These values have been validated against DP measurements using conventional viscometric methods.
منابع مشابه
Aging Study of Oil Impregnated Repulped and Standard Cellulose through Measuring Viscometric Degree of Polymerization
This paper describes the aging behavior of the oil impregnated repulped cellulose and compares it with the aging behavior of the oil impregnated standard cellulose. In order to evaluate the reliability of using repulped cellulose in transformers, the accelerated aging process was applied to both types of cellulose by increasing the temperature to 150 °C and their aging behavior was studied and ...
متن کاملHarmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform
This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...
متن کاملInsulation Fault Diagnosis in High Voltage Power Transformers by Means of Leakage Flux Analysis
Power transformers in service are subjected to a wide variety of electrical, mechanical and thermal stresses capable of producing insulation faults. This type of failure figures amongst the most costly faults in distribution networks since it produces both machine outage and electrical supply interruption. Major research effort has therefore focused on the early detection of faults in the insul...
متن کاملThe Study of Transient Regimes for a Shell-Type Transformer
The transient no-load regime and transient sudden short-circuit regime, of a small power shell-type transformer, will be studied in this paper. Will be determined the current variation in the primary circuit both analytically and by numerical analysis based on finite elements method (FEM). The software used for study is MagNet, developed by the Infolytica Company.
متن کاملModeling the Frequency Response Movements in Power Transformers for Predicting Purposes
Power transformers are key components in electrical power supplies and their failure could cause severe consequences on continuity of service and also generates substantial costs. Identifying problems at an early stage, before catastrophic failure occurs, is a great benefit for reliable operation of power transformers. Frequency Response Analysis (FRA) is a new, well-known and powerful diagnost...