Serum bactericidal testing with the Autobac system.
نویسندگان
چکیده
Current methodology for the serum bactericidal test requires a minimum of 48 h. A procedure was devised for performing this test with the Autobac system (General Diagnostics, Div. Organon Inc., Raleigh, N.C.) in a shortened time span. All titers obtained with the Autobac were compared against results obtained with a standardized tube dilution procedure. The Autobac low-thymidine eugonic broth performed comparably to the tube dilution diluent, a 1:1 ratio of pooled human serum and cation-supplemented Mueller-Hinton broth (99.2% correlation between bactericidal endpoints). Over 300 tests were conducted by using stock reference bacterial strains, clinical isolates, pooled human serum seeded with antimicrobial agents, and serum from patients on antimicrobial therapy. With the Autobac procedure, serum inhibitory titers can be reported in 3 to 4 h (93.4% correlation with the tube dilution procedure). Serum bactericidal titers can be obtained in 24 h without the necessity of subculturing (95.6% correlation). With the exception of staphylococci tested against penicillin, serum bactericidal titers can be obtained in 3 to 4 h (88.4% correlation). The Autobac procedure can provide the clinical laboratory with a rapid, reliable method for performing the serum bactericidal test.
منابع مشابه
Methicillin-resistant Staphylococcus aureus susceptibility testing by an automated system, Autobac I.
The Autobac I system was used to evaluate the antibiotic susceptibility pattern of methicillin-resistant Staphylococcus aureus isolates. The results of the Autobac I were compared with the results of the disk diffusion method. The disk diffusion susceptibility pattern showed resistance to methicillin/oxacillin, penicillin, erythromycin, clindamycin, and kanamycin. All isolates were susceptible ...
متن کاملMethicillin - Resistant Staphylococcus aureus Susceptibility Testing by an Automated System , Autobac I TIMOTHY
The Autobac I system was used to evaluate the antibiotic susceptibility pattern of methicillin-resistant Staphylococcus aureus isolates. The results ofthe Autobac I were compared with the results of the disk diffusion method. The disk diffusion susceptibility pattern showed resistance to methicillin/oxacillin, penicillin, erythromycin, clindamycin, and kanamycin. All isolates were susceptible t...
متن کاملLaboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.
Seven laboratories participated in a collaborative study to evaluate the Autobac 1 system. Results obtained with this assay system were compared to those obtained by the standardized Bauer-Kirby disk diffusion test, and each of these two methods was compared to the agar dilution technique. Comparison of the Autobac 1 and the disk diffusion results from the seven laboratories showed an overall a...
متن کاملEvaluation of the Autobac 1 susceptibility testing system in a clinical diagnostic laboratory.
The Autobac 1 system was compared to the disk diffusion and agar dilution methods. Overall, there was good correlation; however, certain antibiotic/bacterial combinations gave unreliable results. In particular, unreliable results were obtained against staphylococci with penicillins, aerobic gram-negative rods with cephalothin, and enterococci with cephalothin and clindamycin.
متن کاملLaboratory evaluation of amikacin susceptibility testing by the AutoBac I system.
A total of 319 clinical isolates were compared for amikacin susceptibility by AutoBac I and Bauer-Kirby disk diffusion methods. There was an overall agreement of 98.5% between AutoBac I and Bauer-Kirby. An additional 23 strains resistant to amikacin, obtained from Bristol Laboratories, registered a 65% overall agreement. The sensitivity readings differed between the two methods for 13 organisms...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 24 3 شماره
صفحات -
تاریخ انتشار 1986