Slit skiascopic-guided ablation using the Nidek laser.

نویسندگان

  • S MacRae
  • M Fujieda
چکیده

PURPOSE To present the approach of using a scanning slit refractometer (the ARK 10000) in conjunction with a corneal topography system to guide customized corneal ablation. This diagnostic system is coupled with the Nidek EC-5000 system which combines scanning slit and a scanning small area ablation (1.0 mm) to perform a customized ablation. METHODS The ARK 10000 diagnostic system which contains a scanning slit refractometer is described. Information generated from the ARK 10000 wavefront sensor and corneal topography system can be coupled to the new Nidek EC-5000 excimer laser system, which combines the larger area of scanning slit ablation with the small area (1.0 mm) ablation. RESULTS The Nidek ARK 10000 diagnostic system captures wavefront information using a retinoscopic system which is converted into a refractive power map. This is different from other autorefraction systems in that it has four sensors at different diameters of the cornea and captures 1440 points in 0.4 seconds. This map is used in conjunction with corneal topography-captured simultaneously. This information is then combined to perform a customized ablation using the new Nidek EC-5000 system. CONCLUSIONS The ARK 10000 diagnostic system represents a different approach to customized ablation in that it combines a corneal topography system with a wavefront system and a larger treatment area of the traditional scanning slit ablation with a new small area ablation treatment for greater efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavefront- versus topography-guided customized ablations with the NIDEK EC-5000 CX II in surface ablation treatment: refractive and aberrometric outcomes.

PURPOSE To compare the long-term refractive outcomes and changes in higher order wavefront aberrations in patients undergoing photorefractive keratectomy (PRK) with topography-guided (CATz) or wavefront-guided (OPDCAT) ablation algorithm using the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS A retrospective 12-month follow-up study was conducted of 226 eyes undergoing PRK. The ...

متن کامل

Smoothness of ablation on polymethylmethacrylate plates with four scanning excimer lasers.

PURPOSE To perform a quantitative evaluation of smoothness of ablation on polymethylmethacrylate (PMMA) using four scanning excimer lasers available commercially for photorefractive surgery. METHODS Ablations were done on PMMA plates with dimensions 100 x 50 x 1 mm. Four scanning excimer lasers were used, two with flying spot technology (Zeiss-Meditec MEL-70, and a Russian-made unit, Microsca...

متن کامل

CT-guided laser probe for ablation of brain tumors

In this study, 22 patients (15-75 years old) were selected and transferred to CT scan for tumor ablation. For ablations, after prep and drep under the local anesthesia and mild sedation in proper position, small incision made and special needle inserted and guided by proper direction to the core of the tumor. Then, laser probe inserted through the needle and laser energy delivered. Although we ...

متن کامل

Wavefront-guided custom ablation for myopia using the NIDEK NAVEX laser system.

PURPOSE To determine the predictability, efficacy, safety, and stability of LASIK using custom ablation with the NIDEK Advanced Vision Excimer Laser System (NAVEX). METHODS One hundred twenty eyes underwent LASIK for myopia using the OPDCAT algorithm. Refractive outcomes and the change in higher order aberrations, coma, and spherical aberrations were analyzed. Postoperative follow-up ranged f...

متن کامل

Treatment of highly aberrated eyes using the NIDEK CXIII excimer laser.

PURPOSE To describe the treatment of highly aberrated eyes due to previous excimer laser surgery or trauma. METHODS Three eyes (three patients) with reduced visual quality due to previous decentration or corneal laceration (one eye) underwent topography-guided ablation using the CXIII excimer laser (NIDEK Co Ltd) to correct residual refractive error and/or wavefront aberrations. RESULTS Pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 16 5  شماره 

صفحات  -

تاریخ انتشار 2000