Concurrent validity of the PAM accelerometer relative to the MTI Actigraph using oxygen consumption as a reference.

نویسندگان

  • S M Slootmaker
  • M J M Chin A Paw
  • A J Schuit
  • W van Mechelen
  • L L J Koppes
چکیده

The purpose of this study was to examine the concurrent validity of the Personal Activity Monitor (PAM) accelerometer relative to the Actigraph accelerometer using oxygen consumption as a reference, and to assess the test-retest reliability of the PAM. Thirty-two fit, normal weight adults (aged 21-54) performed two activities, treadmill walking and stair walking, while wearing the PAM, the Actigraph and the Cosmed K4b(2). Correlation coefficients and agreement in absolute energy expenditure (EE) levels between PAM, Actigraph and Cosmed were calculated. The test-retest reliability was examined among 296 PAM's using a laboratory shaker. Intraclass correlation coefficients (ICC) and coefficient of variation (CV) were determined. Correlations for treadmill walking and stair walking, respectively, were r(2)=0.95 and r(2)=0.65 for PAM with Actigraph, r(2)=0.82 and r(2)=0.93 for PAM with VO(2) and r(2)=0.64 and 0.74 for Actigraph with VO(2). Both the PAM and Actigraph underestimated EE during treadmill and stair walking by a substantial amount. The test-retest reliability of the PAM was high [ICC=0.80; 95% confidence interval (CI) (0.28;0.92) and intra-CV=1.5%]. The PAM and Actigraph accelerometer are comparable in assessing bodily movement during treadmill and stair walking. The PAM is a valid device to rank subjects in EE and can be useful in collecting objective data to monitor habitual physical activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of the GENEA accelerometer for assessment of physical activity intensity in children.

OBJECTIVES The purpose of the study was to establish activity intensity cut-points for the GENEA accelerometer via calibration with oxygen consumption (V˙⁡O(2)). DESIGN The study was a lab-based validation and calibration study. METHODS Forty-four children, aged 8-14 years, completed eight activities (ranging from lying supine to a medium paced run) whilst wearing GENEA accelerometers at th...

متن کامل

Validity of Fitbit’s active minutes as compared with a research-grade accelerometer and self-reported measures

OBJECTIVES The main purpose of the study was to assess the validity between the Fitbit and ActiGraph GT3X+ accelerometer. The specific aims were to determine the: (1) concurrent validity between the various models of the Fitbit and the GTX3+ accelerometer as the criterion measure for: number of steps and active minutes averaged over a single-day and 7-day period; (2) validity of the two devices...

متن کامل

Validity of treadmill- and track-based individual calibration methods for estimating free-living walking speed and VO2 using the Actigraph accelerometer

BACKGROUND For many patients clinical prescription of walking will be beneficial to health and accelerometers can be used to monitor their walking intensity, frequency and duration over many days. Walking intensity should include establishment of individual specific accelerometer count, walking speed and energy expenditure (VO2) relationships and this can be achieved using a walking protocol on...

متن کامل

Relationship Between the MTI Accelerometer (Actigraph) Counts and Running Speed During Continuous and Intermittent Exercise.

This study was designed to investigate the relationship between Actigraph counts and running speed; and to describe differences due to accelerometer position on the body and due to exercise modality. Eleven physical education students (age, 25.1 ± 3.7 years; height, 1.73 ± 0.10 m; body mass, 70.8 ± 10.8 kg) completed two exhaustive exercise tests (continuous and intermittent), with MTI accelero...

متن کامل

A novel method for using accelerometer data to predict energy expenditure.

The purpose of this study was to develop a new two-regression model relating Actigraph activity counts to energy expenditure over a wide range of physical activities. Forty-eight participants [age 35 yr (11.4)] performed various activities chosen to represent sedentary, light, moderate, and vigorous intensities. Eighteen activities were split into three routines with each routine being performe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scandinavian journal of medicine & science in sports

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2009