Development and validation of an UPLC-MS/MS method for the quantification of ethoxzolamide in plasma and bioequivalent buffers: Applications to absorption, brain distribution, and pharmacokinetic studies

نویسندگان

  • Song Gao
  • Jing Zhao
  • Taijun Yin
  • Yong Ma
  • Beibei Xu
  • Anthony N. Moore
  • Pramod K. Dash
  • Ming Hu
چکیده

The purpose of this study is to develop and validate an UPLC-MS/MS method to quantify ethoxzolamide in plasma (EZ) and apply the method to absorption, brain distribution, as well as pharmacokinetic studies. A C18 column was used with 0.1% of formic acid in acetonitrile and 0.1% of formic acid in water as the mobile phases to resolve EZ. The mass analysis was performed in a triple quadrupole mass spectrometer using multiple reaction monitoring (MRM) with positive scan mode. The results show that the linear range of EZ is 4.88–10,000.00 nM. The intra-day variance is less than 12.43 % and the accuracy is between 88.88–08.00 %. The inter-day variance is less than 12.87 % and accuracy is between 89.27–115.89 %. Protein precipitation was performed using methanol to extract EZ from plasma and brain tissues. Only 40 μL of plasma is needed for analysis due to the high sensitivity of this method, which could be completed in less than three minutes. This method was used to study the pharmacokinetics of EZ in SD rats, and the transport of EZ in Caco-2 and MDCK-MDR1 overexpressing cell culture models. Our data show that EZ is not a substrate for p-glycoprotein (P-gp) and its entry into the brain may not limited by the blood-brain barrier.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

Method development and validation for pharmacokinetic and tissue distributions of ellagic acid using ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

Ellagic acid is a dietary polyphenol found in numerous fruits and vegetables, possessing several health benefits such as antioxidant, anticancer and anti-atherosclerotic biological properties. The purpose of this study was to explore the pharmacokinetics and tissue distribution of ellagic acid in rats. A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method...

متن کامل

A quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...

متن کامل

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 0  شماره 

صفحات  -

تاریخ انتشار 2015