Development of an elution device for ViroCap virus filters
نویسندگان
چکیده
Environmental surveillance of waterborne pathogens is vital for monitoring the spread of diseases, and electropositive filters are frequently used for sampling wastewater and wastewater-impacted surface water. Viruses adsorbed to electropositive filters require elution prior to detection or quantification. Elution is typically facilitated by a peristaltic pump, although this requires a significant startup cost and does not include biosafety or cross-contamination considerations. These factors may pose a barrier for low-resource laboratories that aim to conduct environmental surveillance of viruses. The objective of this study was to develop a biologically enclosed, manually powered, low-cost device for effectively eluting from electropositive ViroCap™ virus filters. The elution device described here utilizes a non-electric bilge pump, instead of an electric peristaltic pump or a positive pressure vessel. The elution device also fully encloses liquids and aerosols that could contain biological organisms, thereby increasing biosafety. Moreover, all elution device components that are used in the biosafety cabinet are autoclavable, reducing cross-contamination potential. This device reduces costs of materials while maintaining convenience in terms of size and weight. With this new device, there is little sample volume loss due to device inefficiency, similar virus yields were demonstrated during seeded studies with poliovirus type 1, and the time to elute filters is similar to that required with the peristaltic pump. The efforts described here resulted in a novel, low-cost, manually powered elution device that can facilitate environmental surveillance of pathogens through effective virus recovery from ViroCap filters while maintaining the potential for adaptability to other cartridge filters.
منابع مشابه
New electropositive filter for concentrating enteroviruses and noroviruses from large volumes of water.
The U.S. Environmental Protection Agency's information collection rule requires the use of 1MDS electropositive filters for concentrating enteric viruses from water, but unfortunately, these filters are not cost-effective for routine viral monitoring. In this study, an inexpensive electropositive cartridge filter, the NanoCeram filter, was evaluated for its ability to concentrate enteroviruses ...
متن کاملDevelopment and application of new positively charged filters for recovery of bacteriophages from water.
Electronegative and electropositive filters were compared for the recovery of indigenous bacteriophages from water samples, using the VIRADEL technique. Fiber glass and diatomaceous earth filters displayed low adsorption and recovery, but an important increase of the adsorption percentage was observed when the filters were treated with cationic polymers (about 99% adsorption). A new methodology...
متن کاملProcessing and transport of environmental virus samples.
Poliovirus-seeded tap water, conditioned with MgCl2 and passed through virus-adsorbing filters, gave better poliovirus recovery than water identically treated but conditioned with AlCl3. Elution of several filter types with beef extract yielded higher recoveries than did elution with glycine. Seeded samples filtered through various filters and stored showed considerable virus loss in 2 days whe...
متن کاملEfficiency of beef extract for the recovery of poliovirus from wastewater effluents.
The efficiency of poliovirus elution from fiber glass cartridge filters (K27), epoxy-fiber glass-asbestos filters (M780), and pleated cartridge filters was assessed by using 3% beef extract (pH 9.0) or 0.1 M glycine (pH 11.5). Poliovirus type I, strain LSc, was seeded into 20- to 25-gallon (ca. 75.6- to 95.6-liter) samples of treated sewage effluent and concentrated by using a filter adsorption...
متن کاملMolecular Detection of Hepatitis A Virus in Urban Sewage in Isfahan, Iran
ABSTRACT Background and Objectives: Hepatitis A virus (HAV) enters sewage through the stool of infected patients and contaminates freshwater and seawater. The aim of present study was quantitative molecular detection of HAV in raw and treated urban sewage samples from Isfahan, center of Iran. &nbs...
متن کامل