Segmented Insert Gradient Coil for Bilateral Knee Imaging
نویسندگان
چکیده
Introduction MRI has become the noninvasive imaging modality of choice for evaluating the knee, because it is faster and avoids the invasive risks of arthroscopy. MRI provides unparalleled soft-tissue detail and contrast compared to other imaging modalities and offers high diagnostic accuracy. MRI of the knee can benefit from high spatial resolution and short echo times for both proton and sodium-23 imaging of cartilage. With higher gradient strength and slew rate, the local insert gradient coils can attain shorter echo times and higher spatial and temporal resolution than the body gradients. Prior flat gradient system designs have achieved relatively small homogeneous-gradient-volumes (HGV) which are not quite wide enough for bilateral knee imaging. To address the challenge of bilateral knee MRI, we have developed a segmented two-region insert gradient system which has two wide HGVs, one for each knee, along the x-axis (left/right). This was achieved by adding an extra vertical plane for wire patterns in the middle of the x-gradient (i.e. in between the two knees) to create high gradient strength. In addition, the planar geometry has been transformed to the superelliptical geometry, which enlarges the HGV dramatically by spreading wire patterns around the imaging anatomy (i.e. both knees). The gradient linearity is improved by using a bi-planar, rather than uni-planar geometry. The transformation method provides an easy and fast optimization tool for bi-planar or superelliptical gradient coil design using a one dimensional stream function. The proposed gradient coil set is designed to image both knees simultaneously, which is an improvement over coils in previous studies [1,2] that can only image one knee at a time, and suffer from cumbersome hardware for opening, closing, and securing the gradient assembly. Methods First, wire patterns were created on a cylindrical surface by using the stream function technique [3]. Next, these wire patterns were transformed onto a superellipse by using a cylinder-to-superellipse transformation [4]. Lastly, a vertical wire pattern is added as shown in Figure 1a to create two separate imaging regions for bilateral knee imaging. The proposed design has width (x, L/R) of 50cm (outer) and 44cm (inner), height (y, A/P) of 36cm (outer) and 30cm (inner), length (z, H/F) of 60cm. Magnetic fields were calculated using Biot-Savart law, and inductance values were obtained using the Neumann method. Results Figure 2 shows the resultant magnetic fields (top row), and gradient fieldmaps (bottom row) for each axis. Contours in the grayscale gradient fieldmaps are at 10% deviations of the field of the gradient from the desired field. The simulated results show that the HGVs are large enough for bilateral knee imaging. (see Table 1) Table 1 also shows detailed gradient performance measures. Conclusion The proposed gradient coil set is designed to image both knees simultaneously, and the simulated results show that the HGVs are large enough for clinical knee imaging. Even though the practical implementation and clinical testing of these coils have not been completed, the simulation results show that conventional planar gradient HGVs can be improved by conversion to the superellipse design. Also, the central x-gradient layer helps to create larger HGVs, facilitates two separate imaging regions, and increases xgradient efficiency (up to 249 mT/m at 300A). Further applications of this work might include, bilateral imaging of the ankle, feet, wrists, and small animals. References [1] Crozier S et al., JMR; 139:81-89, 1999. [2] Petropoulos LS et al., US Patent 6,788,057, 2004. [3] Tomasi D, MRM; 45:505-512, 2001. [4] Moon SM et al., MRM, 2009. (in review) Acknowledgments This work is supported by Siemens Medical Solutions, the Ben B. and Iris M. Margolis Foundation, and NIH 5R33 EB004803. a
منابع مشابه
Superelliptical insert gradient coil with a field-modifying layer for breast imaging.
Many MRI applications such as dynamic contrast-enhanced MRI of the breast require high spatial and temporal resolution and can benefit from improved gradient performance, e.g., increased gradient strength and reduced gradient rise time. The improved gradient performance required to achieve high spatial and temporal resolution for this application may be achieved by using local insert gradients ...
متن کاملInsert Dome Gradient Coils for Brain Imaging
J. Leggett, D. Green, R. Bowtell Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, United Kingdom Introduction Insert gradient coils offer significant advantages for brain imaging as a result of the large increase in gradient performance that is achieved as the coil size is reduced. It has been shown previously that head-sized ...
متن کاملReduced Susceptibility Artifacts in Diffusion Weighted Brain Imaging Using Specialized RF and Gradient Hardware
INTRODUCTION: Diffusion Weighted Imaging (DWI) techniques have improved due to increased magnetic field strength and improved Radio Frequency (RF) and gradient coil performance[1]. Improved gradient performance is used to shorten the echotrain duration and increase the number of echoes in the same duration, thereby reducing susceptibility artifacts[2,3]. In this study, we combine a home-built i...
متن کاملDiscrete Design of an Insert Gradient Coil for Head Imaging in High Field MRI
S. Shvartsman, G. DeMeester, M. Morich Philips Medical Systems, Cleveland, Ohio, United States Introduction In this work we present designs for a transverse head insert gradient coil using a discrete coil design method. The targets for the gradient are: 60mT/m gradient strength, 600mT/m/ms slew rate, and 24cm Field-of-View (FoV). The gradient is sized to fit within a whole body gradient coil. I...
متن کاملImprovement of DTI measurement using the Composite Gradient Systems on a Clinical 3T MRI System: DTI study of ex vivo Dog's Heart
INTRODUCTION: Diffusion Tensor Imaging (DTI) techniques have improved due to increased magnetic field strength and improved RF and gradient coil performance. Further improvement in gradient performance could be used to shorten the echotrain duration or increase the number of echoes in the same duration and thereby be of substantial benefit for high resolution DTI acquisition. Although, insert g...
متن کامل