Quantitative analysis of hypoperfusion in acute stroke: arterial spin labeling versus dynamic susceptibility contrast.

نویسندگان

  • Kambiz Nael
  • Arash Meshksar
  • David S Liebeskind
  • Bruce M Coull
  • Elizabeth A Krupinski
  • J Pablo Villablanca
چکیده

BACKGROUND AND PURPOSE This study compares the concordance between arterial spin labeling (ASL) and dynamic susceptibility contrast (DSC) for the identification of regional hypoperfusion and diffusion-perfusion mismatch tissue classification using a quantitative method. METHODS The inclusion criteria for this retrospective study were as follows: patients with acute ischemic syndrome with symptom onset <24 hours and acquisition of both ASL and DSC MR perfusion. The volumes of infarction and hypoperfused lesions were calculated on ASL and DSC multi-parametric maps. Patients were classified into reperfused, matched, or mismatch groups using time to maximum >6 sec as the reference. In a subset of patients who were successfully recanalized, the identical analysis was performed and the infarction and hypoperfused lesion volumes were used for paired pre- and posttreatment comparisons. RESULTS Forty-one patients met our inclusion criteria. Twenty patients underwent successful endovascular revascularization (TICI>2a), resulting in a total of 61 ASL-DSC data pairs for comparison. The hypoperfusion volume on ASL-cerebral blood flow best approximated the DSC-time to peak volume (r=0.83) in pretreatment group and time to maximum (r=0.46) after recanalization. Both ASL-cerebral blood flow and DSC-TTP overestimated the hypoperfusion volume compared with time to maximum volume in pretreatment (F=27.41, P<0.0001) and recanalized patients (F=8.78, P<0.0001). CONCLUSIONS ASL-cerebral blood flow overestimates the DSC time to maximum hypoperfusion volume and mismatch classification in patients with acute ischemic syndrome. Continued overestimation of hypoperfused volume after recanalization suggests flow pattern and velocity changes in addition to arterial transit delay can affects the performance of ASL.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Combined low-dose contrast-enhanced MR angiography and perfusion for acute ischemic stroke at 3T: A more efficient stroke protocol.

BACKGROUND AND PURPOSE There is need to improve image acquisition speed for MR imaging in evaluation of patients with acute ischemic stroke. The purpose of this study was to evaluate the feasibility of a 3T MR stroke protocol that combines low-dose contrast-enhanced MRA and dynamic susceptibility contrast perfusion, without additional contrast. METHODS Thirty patients with acute stroke who un...

متن کامل

Multi-delay multi-parametric arterial spin-labeled perfusion MRI in acute ischemic stroke — Comparison with dynamic susceptibility contrast enhanced perfusion imaging☆

The purpose of the present study was to present a multi-delay multi-parametric pseudo-continuous arterial spin labeling (pCASL) protocol with background suppressed 3D GRASE (gradient and spin echo) readout for perfusion imaging in acute ischemic stroke. PCASL data at 4 post-labeling delay times (PLD = 1.5, 2, 2.5, 3 s) were acquired within 4.5 min in 24 patients (mean age 79.7 ± 11.4 years; 11 ...

متن کامل

The value of arterial spin-labeled perfusion imaging in acute ischemic stroke: comparison with dynamic susceptibility contrast-enhanced MRI.

BACKGROUND AND PURPOSE The purpose of this study was to evaluate the potential clinical value of arterial spin-labeled (ASL) perfusion MRI in acute ischemic stroke (AIS) through comparison with dynamic susceptibility contrast (DSC) enhanced perfusion MRI. METHODS Pseudocontinuous ASL with 3-dimensional background-suppressed gradient and spin echo readout was applied with DSC perfusion MRI on ...

متن کامل

Arterial Spin Labeling Perfusion Magnetic Resonance Imaging Performed in Acute Perinatal Stroke Reveals Hyperperfusion Associated With Ischemic Injury.

BACKGROUND AND PURPOSE Perfusion-weighted imaging in adults with acute stroke often reveals hypoperfusion in the ischemic core and in a surrounding area of nondiffusion-restricted penumbral tissue. Perinatal stroke is common, but the perfusion pattern is rarely documented. We aimed to describe the perfusion pattern in newborns with perinatal stroke. METHODS Neonates with clinical features of ...

متن کامل

Assessing reperfusion with whole-brain arterial spin labeling: a noninvasive alternative to gadolinium.

BACKGROUND AND PURPOSE Arterial spin labeling (ASL) is a perfusion imaging technique that does not require gadolinium. The study aimed to assess the reliability of ASL for evaluating reperfusion in acute ischemic stroke in comparison with dynamic susceptibility contrast (DSC) imaging. METHODS The study included 24 patients with acute ischemic stroke on admission and 24-hour follow-up ASL and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 44 11  شماره 

صفحات  -

تاریخ انتشار 2013