v 1 1 7 Ju n 20 05 Time resolution of Burle 85001 micro - channel plate photo - multipliers in comparison with Hamamatsu R 2083
نویسندگان
چکیده
Time resolution of Burle 85001 micro-channel plate photo-multipliers in comparison with Hamamatsu R2083. Abstract The CLAS detector will require improvements in its particle identification system to take advantage of the higher energies provided by the Jefferson Laboratory accelerator upgrade to 12 GeV. To this end, we have studied the timing characteristics of the micro-channel plate photo-multiplier 85001 from Burle, which can be operated in a high magnetic field environment. For reference and comparison, measurements were also made using the standard PMT R2083 from Hamamatsu using two timing methods. The cosmic ray method, which utilizes three identical scintillating counters 2 × 3 × 50 cm 3 with PMs at the ends, yields σ R2083 = 59.1 ± 0.7 ps. The location method of particles from radiative source with known coordiantes has been used to compare timing resolutions of R2083 and Burle − 85001. This " coordinate method " requires only one counter instrumented with two PMs and it yields σ R2083 = 59.5 ± 0.7 ps in agreement with the cosmic ray method. For the micro-channel plate photomultiplier from Burle with an external amplification of 10 to the signals, the coordinate method yields σ 85001 = 130 ± 4 ps. This method also makes it possible to estimate the number of primary photo-electrons.
منابع مشابه
ar X iv : a st ro - p h / 05 06 26 1 v 1 1 3 Ju n 20 05 Laboratory simulation of cometary x rays using a high - resolution microcalorimeter
X-ray emission following charge exchange has been studied on the University of California Lawrence Livermore National Laboratory electron beam ion traps EBITI and EBIT-II using a high-resolution microcalorimeter. The measured spectra include the K-shell emission from hydrogenlike and heliumlike C, N, O, and Ne needed for simulations of cometary x-ray emission. A comparison of the spectra produc...
متن کاملA 5 ps TOF - counter with an MCP – PMT
We measured the timing resolution of TOF counters by means of Cherenkov-light detection with a Micro-Channel Plate PhotoMultiplier Tube, and attained sTOF 1⁄4 6:2 ps using 3GeV=c pion-beams with a readout electronics of 4.1 ps resolution. The optimum radiator thickness was examined and the detectable number of photo-electrons was analyzed. r 2006 Elsevier B.V. All rights reserved. PACS: 85.60.H...
متن کاملMCP-PMT timing property for single photons
We have measured the performance, especially the timing properties, of micro-channel plate photo-multiplier tubes (MCP-PMTs) by irradiating with single photons with/without a magnetic field. A time resolution of s 1⁄4 30–35 ps was obtained for single photons under 1:5 T: With an MCP-PMT, a small time-of-flight counter, by means of Cherenkov light radiation instead of scintillation light has bee...
متن کامل/ 05 06 21 7 v 1 2 7 Ju n 20 05 Entanglement of pair cat states and teleportation
The entanglement of pair cat states in the phase damping channel is studied by employing the relative entropy of entanglement. It is shown that the pair cat states can always be distillable in the phase damping channel. Furthermore, we analyze the fidelity of teleportation for the pair cat states by using joint measurements of the photon-number sum and phase difference. PACS number: 03.67.-a, 0...
متن کاملA LAAPD based calibration system for FOPIs new MMRPC-barrel
T.I. Kang1,3, M. Ciobanu1,2, M. Kiš1, A. Schüttauf1, K.D. Hildenbrand1, Y.J. Kim1, P. Koczon1, Y. Leifels1, X. Lopez1, M. Marquard1, M.S. Ryu1,3, J.Weinert1, N. Zernezki1,2, X. Zhang1, and the FOPI Collaboration 1GSI, Darmstadt, Germany; 2Universität Heidelberg, Germany; 3Korea University, Seoul, South Korea FOPI’s new ToF-barrel based on MMRPCs [1] uses a new custom designed readout electronic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005