Dynamics of 1:2 Coordination: Temporal Scaling, Latent 1:1, and Bistability.
نویسندگان
چکیده
The simplest interlimb multifrequency coordination of 1:2 can be performed at different speeds and in at least two different styles or modes. The effects of speed and mode (in-phase or antiphase) were evaluated in a bimanual 1:2 rhythmic task in which participants (N = 8) oscillated hand-held pendulums with identical or different uncoupled frequencies. A motion equation in relative phase that captures the asymmetries of components and task predicted the 1:2 coordination equilibria resulting from temporal scaling. According to the experimental results, both coordination modes proved to be equally stable. More detailed analyses of individual trials showed signs that the more fundamental 1:1 coordination intruded into the 1:2 coordination.
منابع مشابه
Recurrence Quantification as an Analysis of Temporal Coordination with Complex Signals
Ample past research demonstrates that human rhythmic behavior and 1 rhythmic coordination reveal complex dynamics. More recently, researchers have 2 begun to examine the dynamics of coordination with complex, fractal signals. Here, 3 we present preliminary research investigating how recurrence quantification tech4 niques might be applied to study temporal coordination with complex signals. 5 Pa...
متن کاملPrevalence of Rate-Dependent Behaviors in Cardiac Muscle
We explore the rate-dependent dynamic response of periodically paced bullfrog (Rana catesbeiana) cardiac muscle. Alternans (2:2 behavior) occur in 35% of animals and 2:1 $ 1:1 bistability in 74% of animals. In addition, we observe 2:2 $ 2:1 bistablility. We discuss the implications of these results for two map-based models of cardiac dynamics. The high prevalence of bistability suggests that th...
متن کاملExistence of bistability and correlation with arrhythmogenesis in paced sheep atria.
INTRODUCTION Studies of the electrical dynamics of cardiac tissue are important for understanding the mechanisms of arrhythmias. This study uses high-frequency pacing to investigate the dynamics of sheep atria. METHODS AND RESULTS A 504-electrode mapping plaque was affixed to the right atrium in six sheep. Cathodal pacing stimuli were delivered to the center of the plaque. Pacing period (Tp) ...
متن کاملReentrant Waves Induced by Local Bistabilities in a Cardiac Model
Rate-dependent bistability and hysteresis have recently been observed to be highly prevalent in periodically stimulated bullfrog ventricular muscle. Similar bistabilities have been found in in vivo sheep atria at interstimulus intervals for which spatiotemporally complex behaviors, possibly atrial flutter and fibrillation, are observed. Might bistability play a role in the onset of spatiotempor...
متن کاملTemporal scaling of groundwater discharge in dual and multicontinuum catchment models
[1] This paper presents a multicontinuum approach to model fractal temporal scaling of catchment response in hydrological systems. The temporal scaling of discharge is quantified in frequency domain by the transfer function HðxÞ, which is defined as the ratio between the spectra of catchment response and recharge time series. The transfer function may scale with frequency x as HðxÞ x2b. While t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of motor behavior
دوره 31 3 شماره
صفحات -
تاریخ انتشار 1999