A comparison of the systemic bioactivity of inhaled budesonide and fluticasone propionate in normal subjects.
نویسندگان
چکیده
1. The aim of this study was to compare the systemic bioactivity of low and high doses of inhaled budesonide and fluticasone propionate given by respective dry powder inhaler devices. 2. A randomised, single blind cross-over design was used in nine healthy subjects who were given 800 micrograms day-1 of budesonide Turbohaler (B800) for 1 week, followed by 1 week of 1600 micrograms day-1 (B1600), or fluticasone Diskhaler 750 micrograms day-1 (F750) for 1 week followed by 1 week of 1500 micrograms day-1 (F1500). There was a 1 week washout between treatments with fluticasone or budesonide. A twice daily dosing regime was used and mouth-rinsing was employed to reduce gut bioavailability as well as to obviate local adverse effects. 3. Parameters of hypothalmic-pituitary adrenal (HPA) axis activity and bone metabolism were measured at baseline (B0/F0), at the end of each week of treatment and after the 1 week washout (F0 or B0). 4. Both fluticasone and budesonide significantly (P < 0.05) attenuated the post tetracosactrin serum cortisol at low and high doses whilst early morning cortisol was unchanged. No dose-response effect was observed with either drug, and there was no significant difference between treatment with fluticasone or budesonide. 5. Neither budesonide nor fluticasone produced significant suppression of plasma osteocalcin, although the higher doses of both drugs significantly reduced fasting urinary calcium levels.(ABSTRACT TRUNCATED AT 250 WORDS)
منابع مشابه
Adrenal suppression with inhaled budesonide and fluticasone propionate given by large volume spacer to asthmatic children.
BACKGROUND The aim of this study was to compare the systemic bioactivity of inhaled budesonide (B) and fluticasone propionate (F), each given by large volume spacer, on a microgram equivalent basis in asthmatic children. METHODS Ten stable asthmatic children of mean age 11 years and forced expiratory volume in one second (FEV1) 81.6% predicted, who were receiving treatment with < or = 400 mic...
متن کاملComparison of the systemic effects of fluticasone propionate and budesonide given by dry powder inhaler in healthy and asthmatic subjects.
BACKGROUND The potential for long term adverse effects from inhaled corticosteroids relates to their systemic absorption, usually assessed from proxy markers in short term studies. When fluticasone propionate and budesonide have been compared in this way the results have been inconsistent. To determine whether this is because of the subjects studied or the sensitivity of the systemic marker use...
متن کاملComparison of the systemic eVects of fluticasone propionate and budesonide given by dry powder inhaler in healthy and asthmatic subjects
Background—The potential for long term adverse eVects from inhaled corticosteroids relates to their systemic absorption, usually assessed from proxy markers in short term studies. When fluticasone propionate and budesonide have been compared in this way the results have been inconsistent. To determine whether this is because of the subjects studied or the sensitivity of the systemic marker used...
متن کاملPlasma concentrations of fluticasone propionate and budesonide following inhalation from dry powder inhalers by healthy and asthmatic subjects.
BACKGROUND All currently available inhaled corticosteroids reach the systemic circulation and have the potential to produce adverse effects with long term use. This risk is often assessed by measuring the effect of different inhaled corticosteroids on the hypothalamic-pituitary-adrenal (HPA) axis in healthy subjects. Absorption of fluticasone propionate and its effects on the HPA axis are great...
متن کاملComparative adrenal suppression with inhaled budesonide and fluticasone propionate in adult asthmatic patients.
BACKGROUND A study was performed to compare the adrenal suppression caused by inhaled fluticasone propionate and budesonide on a microgram equivalent basis, each given by metered dose inhaler to asthmatic patients. METHODS Twelve asthmatic patients of mean age 29.9 years, with a forced expiratory volume in one second (FEV1) 92.9% predicted and forced expiratory flow 25-75% (FEF25-75) 69.5% pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of clinical pharmacology
دوره 38 6 شماره
صفحات -
تاریخ انتشار 1994