Serial change in airway lumen and wall thickness at thin-section CT in asymptomatic subjects.

نویسندگان

  • Shin Matsuoka
  • Yasuyuki Kurihara
  • Yasuo Nakajima
  • Hiroshi Niimi
  • Hiroshi Ashida
  • Katsuhiko Kaneoya
چکیده

PURPOSE To retrospectively analyze serial changes in airway lumen and wall thickness (WT) at multi-detector row computed tomography (CT) in asymptomatic subjects. MATERIALS AND METHODS Institutional review board did not require its approval or informed patient consent. Airway dimensions were analyzed in 52 patients (30 men and 22 women) without known cardiopulmonary disease. Contiguous 2-mm CT sections were obtained after reconstruction, extending from origin of right posterior basal segmental bronchi to posterior subsegmental bronchi. Following parameters were determined with semiautomatic image-processing program: luminal area (LA), total airway area (TA), short axis of lumen (LSD), and short axis of total airway (TSD). In airways in which adjacent vessel or branching of small bronchus abutted boundary of airway, extrapolated line was traced by one radiologist. Airway wall area (WA) was calculated as TA - LA, and WT was calculated as (TSD - LSD)/2. Relative WA (WA% = [WA/TA] . 100) and ratio of airway WT to total diameter (D) (WT/D = WT/TSD) were calculated. Linear regression analysis and Spearman rank correlation were used to evaluate relationship between airway parameters (LA, WA%, and WT/D ratio) and distance from origin of segmental bronchi. RESULTS LA decreased as CT proceeded from hilum to periphery (r = -0.765, P < .001). In 308 (32.7%) of 943 bronchi, however, LA increased as CT proceeded from hilum to periphery. LA increased by 10% or more in 101 (10.7%) of 943 bronchi. Mean changes in WA% and WT/D ratio between two contiguous sections were 0.66 +/- 5.05 (standard deviation) and 0.003 +/- 0.024, respectively. WA% changed by more than 5% between two contiguous sections in 274 (29.0%) of 943 bronchi. WT/D ratio changed by more than 0.02 between two contiguous sections in 338 (35.8%) of 943 bronchi. CONCLUSION Variation of airway lumen and WT is found in asymptomatic subjects without known cardiopulmonary disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thin-section CT evidence of bronchial thickening in children with stable asthma: bronchoconstriction or airway remodeling?

RATIONALE AND OBJECTIVES The authors performed this study to determine if bronchial wall thickening is present in children with moderate to severe asthma during periods free from clinical bronchoconstriction. MATERIALS AND METHODS The authors obtained low (radiation) dose thin-section computed tomographic (CT) scans in each of 18 control subjects and 21 children with moderately severe but sta...

متن کامل

Optimal scanning protocols of 64-slice CT angiography in coronary artery stents: an in vitro phantom study.

PURPOSE The purpose of the study was to investigate the optimal scanning protocol of 64-slice CT angiography for assessment of coronary artery stents based on a phantom study. MATERIALS AND METHODS Coronary stents with a diameter of 2.5mm was implanted in thin plastic tubes with an inner diameter of 3.0mm to simulate a coronary artery. The tubes were filled with iodinated contrast medium dilu...

متن کامل

Airway dimensions in asthma and COPD in high resolution computed tomography: can we see the difference?

BACKGROUND Airway remodeling in asthma and COPD results in bronchial wall thickening. The thickness of the bronchial wall can be measured in high-resolution computed tomography. The objectives of the study were to assess the bronchial lumen and wall dimensions in asthma and COPD patients, in relation to disease severity, and to compare the airway dimensions in patients with asthma and COPD. M...

متن کامل

Semi-Automatic Measurement of the Airway Dimension by Computed Tomography Using the Full-With-Half-Maximum Method: a Study of the Measurement Accuracy according to the Orientation of an Artificial Airway

OBJECTIVE To develop an algorithm to measure the dimensions of an airway oriented obliquely on a volumetric CT, as well as assess the effect of the imaging parameters on the correct measurement of the airway dimension. MATERIALS AND METHODS An airway phantom with 11 poly-acryl tubes of various lumen diameters and wall thicknesses was scanned using a 16-MDCT (multidetector CT) at various tilt ...

متن کامل

Comparison of the Effect of ProTaper and Gates-Glidden Drills On the Remaining Root Dentin Thickness at the Coronal Region of the Root

Background and Aim: The purpose of this study was to evaluate residual dentin thickness of the root and the area of the canal lumen in the coronal region of the mesiobuccal and mesiolingual canals of the lower first molars after canal preparation with the common method of using hand files and Gates Glidden drills or ProTaper rotary files, by Spiral Ct-Scan. Materials and Methods: In this exp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 234 2  شماره 

صفحات  -

تاریخ انتشار 2005