Analysis of the harmonic content of the tidal flow waveforms in infants.

نویسندگان

  • U Frey
  • M Silverman
  • B Suki
چکیده

The aim of this study was to examine whether the spectral characteristics of tidal flow waveform reflect the interaction between the control of breathing and lung mechanics in 10 healthy infants (H), 10 infants with a history of wheezing disorders (W), and 10 infants with chronic lung disease (CLD). From the flow waveform, we calculated a shape index, the harmonic distortion (k(d)), which quantifies the extent to which a periodic signal deviates from a sine wave. The k(d) of the entire tidal flow waveform did not significantly discriminate between diagnostic groups. However, k(d) was sensitive to maturation: it increased from 0.26 at 1 mo to 0.37 at 6 mo of age (P < 0.002). Furthermore, the frequency (f) spectra of the flow (V) amplitudes between 0.13 and 10 Hz followed a power law: V(f) approximately f(-s), where s (slope) is the exponent in the power law. The exponent of the healthy infants s(H) was 4.24 [95% confidence interval (CI) = 0.2] at 1 mo, 4.39 (CI = 0.16) at 6 mo, and 4.35 (CI = 0.19) at 12 mo and not significantly changing with age. The mean value of s(W) was marginally lower (4.09 +/- 0.28; P < 0.05) than that of s(H). The mean s(CLD) was significantly lower (3.04 +/- 0.31; P < 0.001). Lower values of s and higher values of k(d) indicate an increased complexity of the feedback mechanisms determining tidal flow waveform and may be associated with disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

An Intelligent Method Based on WNN for Estimating Voltage Harmonic Waveforms of Non-monitored Sensitive Loads in Distribution Network

An intelligent method based on wavelet neural network (WNN) is presented in this study to estimate voltage harmonic distortion waveforms at a non-monitored sensitive load. Voltage harmonics are considered as the main type of waveform distortion in the power quality approach. To detect and analyze voltage harmonics, it is not economical to install power quality monitors (PQMs) at all buses. The ...

متن کامل

Determination of Compound and Overtide Constituents near the Eastern Iranian Coast of Makran

In this study, the compound and overtide constituents resulted from nonlinear triad interactions were evaluated using Bispectral method at the eastern Iranian coasts of Makran. It was found that the most significant compound constituents at the studies area were KO2, KP2, MS4 and MN4. Also, the overtides of M4 and S4 were detectable by means of implemented method. The superiority of Bispectral ...

متن کامل

Least Squares Analysis of Noise-Free Tides Using Energy Conservation and Relative Concentration of Periods Criteria

In this article, a new approach to tidal harmonic analysis is introduced. This approach incorporates more constituents in the least squares method for a fixed duration of noise-free tidal record and results in a more accurate tidal prediction. Moreover, it is demonstrated that 135 days of hourly data, which is significantly less than 369 days data in the Rayleigh criterion, is sufficient for th...

متن کامل

Harmonic Modeling of Inrush Current in Core Type Power Transformers Using Hartley Transform

This paper presents a new method for evaluation and simulation of inrush current in various transformers using operational matrices and Hartley transform. Unlike most of the previous works, time and frequency domain calculations are conducted simultaneously. Mathematical equations are first represented to compute the inrush current based on reiteration and then Hartley transform is used to stud...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 91 4  شماره 

صفحات  -

تاریخ انتشار 2001