Comparison of cone-beam computed tomography with intraoral photostimulable phosphor imaging plate for diagnosis of endodontic complications: a simulation study.
نویسندگان
چکیده
OBJECTIVES The objective of this study was to compare the sensitivity and reliability of cone-beam computed tomography (CBCT) and intraoral photostimulable phosphor (PSP) imaging plate for diagnosis of endodontic complications. STUDY DESIGN Seventy-two human mandibular teeth were used, including 24 incisors/canines, 24 premolars, and 24 molars. Three images were taken from each group of teeth with intraoral PSP, CBCT-NewTom, and CBCT-ProMax. RESULTS The sensitivity of PSP, CBCT-NewTom, and CBCT-ProMax was 76.39%, 80.56%, and 94.44% for detecting cast post deviation; 98.61%, 100%, and 100% for external root resorption; 86.11%, 31.94%, and 36.11% for fractured file; and 66.67%, 90.28%, and 86.11% for lateral root perforation respectively. The intertechnique reliability (kappa statistics) was 58.4% for the 2 CBCT techniques, 20.1% and 18.8% for CBCT-NewTom and CBCT-ProMax versus PSP respectively. CONCLUSIONS Given strengths and weaknesses of the techniques as well as the cost, CBCT is recommended as a complementary but not routinely used diagnostic method for endodontic complications not usually detected by conventional methods.
منابع مشابه
Comparison of cone-beam computed tomography with intraoral photostimulable phosphor imaging plate for diagnosis of endodontic complications: a simulation study
متن کامل
Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملComparison of Cone Beam Computerized Tomography and Phosphor Storage Plate in Detecting Artificial Buccal Recurrent Caries
Introduction Recurrent or secondary caries develops at the margin of restorations and causes restorative failure. We conducted this study to compare the performance of Phosphor Storage Plate (PSP) and Cone Beam Computed Tomography (CBCT) scan in detecting buccal recurrent caries under amalgam and composite resin restorations. Materials and Methods Class V cavities were prepared on the buccal...
متن کاملDiagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption.
AIM To compare in an ex vivo model the ability of digital intraoral radiography and cone beam computed tomography (CBCT) to detect simulated external inflammatory root resorption lesions, and to investigate the effect of altering the degree of rotation of the CBCT scanners X-ray source and imaging detector on the ability to detect the same lesions. METHODOLOGY Small and large simulated extern...
متن کاملA Comparative Study of Diagnostic Accuracy of Cone Beam Computed Tomography and Intra Oral Digital Radiography Phosphor Storage Plates in Detecting Strip Perforation in Endodontically-Treated Teeth
Background and purpose: Perforation impairs the prognosis of endodontic treatments, so, timely and accurate diagnosis is important. For this purpose, various radiographic diagnostic tools have been studied to select the method that has the least complications and helps in making the most accurate diagnosis. This study aimed to compare the accuracy of cone beam computed tomography (CBCT) and int...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Oral surgery, oral medicine, oral pathology and oral radiology
دوره 114 6 شماره
صفحات -
تاریخ انتشار 2012