Management of Retained Intervention Guide-wire: A Literature Review

نویسندگان

  • Abdulrahman M Al-Moghairi
  • Hussein S Al-Amri
چکیده

Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subretinal Perfluorocarbon Liquid (PFCL) after Vitrectomy; A Case Report And Review of Literature

Purpose: To report a case of retained subretinal perfluorocarbon liquid (PFCL) after vitrectomy and to discuss the diagnosis and management of subretinal PFCL based on literature review. Case Report: A 57-year-old female patient underwent 3-port 23-gauge vitrectomy for advanced proliferative diabetic retinopathy and combined tractional and rhegmatogenous retinal detachment. During the surgery, ...

متن کامل

Wireless Connection between Guide Wires and Bone Cement: Extravasated Methyl Methacrylate Mimicking a Retained Guide Wire

We present the case of a 56-year-old double lung transplant recipient with chest pain who underwent an attempted endovascular retrieval of what was described as a retained guide wire in the azygos vein. After successfully grasping the tip, the object further migrated to the right pulmonary artery complicating the retrieval. It was realized that the "wire" was extravasated methyl methacrylate fr...

متن کامل

Skeletal Sarcoma on the Site of Retained War Bullet Fragments and a Literature Review on Long-Term Complications of Retained War Shells

  Long-term complications of retained war fragments in the body are not completely known. Also, bullet migration and slow resorption of metals and distortion in some imaging modalities are frequent and well recognized complications but, now we are concerned about neoplastic changes near the retained war fragments. We reviewed the literature on complication of retained war fragments and report o...

متن کامل

Guide Wire Loss of Femoral Venous Cannulation: Case Report and Literature Review.

Placement of a central venous catheter (CVC) is a common procedure, often replaced by femoral vein cannulation. The overall complication rate is 12 - 15%. Loss of a complete guide wire into the circulation is a rare and preventable complication. Here we report a case of guide wire loss during femoral venous cannulation and literature review.

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013