The Effect of Subcutaneous Fat on Electrical Impedance Myography: Electrode Configuration and Multi-Frequency Analyses

نویسندگان

  • Le Li
  • Xiaoyan Li
  • Huijing Hu
  • Henry Shin
  • Ping Zhou
چکیده

This study investigates the impact of the subcutaneous fat layer (SFL) thickness on localized electrical impedance myography (EIM), as well as the effects of different current electrodes, varying in distance and direction, on EIM output. Twenty-three healthy subjects underwent localized multi-frequency EIM on their biceps brachii muscles with a hand-held electrode array. The EIM measurements were recorded under three different configurations: wide (or outer) longitudinal configuration 6.8 cm, narrow (or inner) longitudinal configuration 4.5 cm, and narrow transverse configuration 4.5 cm. Ultrasound was applied to measure the SFL thickness. Coefficients of determination (R2) of three EIM variables (resistance, reactance, and phase) and SFL thickness were calculated. For the longitudinal configuration, the wide distance could reduce the effects of the subcutaneous fat when compared with the narrow distance, but a significant correlation still remained for all three EIM parameters. However, there was no significant correlation between SFL thickness and reactance in the transverse configuration (R2 = 0.0294, p = 0.434). Utilizing a ratio of 50kHz/100kHz phase was found to be able to help reduce the correlation with SFL thickness for all the three configurations. The findings indicate that the appropriate selection of the current electrode distance, direction and the multi-frequency phase ratio can reduce the impact of subcutaneous fat on EIM. These settings should be evaluated for future clinical studies using hand-held localized arrays to perform EIM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of subcutaneous fat on electrical impedance myography when using a handheld electrode array: the case for measuring reactance.

OBJECTIVE Recent developments in electrical impedance myography (EIM) have led to the use of handheld electrode arrays (HEAs) for data acquisition. Although preferable for several reasons, this approach tends to be more affected by subcutaneous fat (SF) than the original approach in which the impedance-measuring electrodes are widely spaced. In this study, we seek to identify the EIM parameter ...

متن کامل

The Effect of Gold Nanoparticle on Electrical Impedance of Tissue on Low Frequency Ranges

Introduction: Electrical impedance of tissues on low frequencies includes useful information about functional and structural changes in tissues. This property is used in Electrical Impedance Tomography (EIT) imaging modality for the detection of lesions in tissues.Objective: The goal of this article is to study changes in electrical impedance of tissues in the presence of gold nanoparticles.Mat...

متن کامل

Assessment of Optimized Electrode Configuration for Electrical Impedance Myography Using Genetic Algorithm via Finite Element Model

Electrical Impedance Myography (EIM) is a noninvasive neurophysiologic technique to diagnose muscle health. Besides muscle properties, the EIM measurements vary significantly with the change of some other anatomic and nonanatomic factors such as skin fat thickness, shape and thickness of muscle, and electrode size and spacing due to its noninvasive nature of measurement. In this study, genetic ...

متن کامل

A Reconfigurable Electrode Array for Use in Rotational Electrical Impedance Myography

This thesis describes the design of a novel handheld electrode probe and measurement system for use in rotational electrical impedance myography (EIM), which is a method for diagnosing neuromuscular disease. The probe can be controlled from a PC via USB and uses an array of small electrode cells that can be connected together into larger electrodes with the help of crosspoint switches. A measur...

متن کامل

Electrical impedance myography in spinal muscular atrophy: a longitudinal study.

INTRODUCTION New approaches for assessing disease progression in spinal muscular atrophy (SMA) are needed. In this study, we evaluate whether electrical impedance myography (EIM) can detect disease progression in SMA compared with a group of healthy children of similar age. METHODS Twenty-eight children with SMA and 20 normal children underwent repeated EIM testing in four muscles at regular ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016