Achievement of hearing preservation in the presence of an electrode covering the residual hearing region
نویسندگان
چکیده
CONCLUSIONS With full insertion with a long electrode, hearing preservation can be achieved even in the presence of a long electrode covering the residual hearing region. OBJECTIVES Advances in developing new atraumatic concepts of electrode design as well as surgical technique have enabled hearing preservation after cochlear implantation surgery, and EAS (electric acoustic stimulation) accompanied with hearing preservation is a new trend for patients with residual hearing at the lower frequencies. However, full insertion with a long/medium electrode and hearing preservation is still a challenging field that calls for discussion. METHOD In this study, round window insertion, an atraumatic electrode, and dexamethasone administration were used and atraumaticity (hearing preservation and conservation of vestibular function) was evaluated with full insertion of the electrode. RESULTS Postoperative evaluation after full insertion of the electrodes showed that hearing at low frequencies was well preserved in all five cases. Combined postoperative imaging with the referential tonotopic map confirmed achievement of full insertion and indicated the corresponding frequencies and the depth of the electrode. Achievement of atraumaticity of round window insertion in the present cases was confirmed from the viewpoint of the minimal drilling time as well as the preserved vestibular function.
منابع مشابه
Hearing Preservation in Cochlear Implant Surgery
In the past, it was thought that hearing loss patients with residual low-frequency hearing would not be good candidates for cochlear implantation since insertion was expected to induce inner ear trauma. Recent advances in electrode design and surgical techniques have made the preservation of residual low-frequency hearing achievable and desirable. The importance of preserving residual low-frequ...
متن کاملInvestigating the Effect of Cochlear Size in Insertion of Electrode Depth in Patients with Cochlear Implantation evaluated by CT-Scan
Background Cochlear implant surgery is an invasive procedure for patients with bilateral Sensorineural hearing loss and may cause some risks such as cochlear damage. We aimed to evaluate the effectiveness of cochlear measures obtained by computed tomography (CT) scan in predicting depth of cochlear implant insertion. Materials and Methods This study was conducted in a retrospective and cross-se...
متن کاملComparison of the Pediatric Cochlear Implantation Using Round Window and Cochleostomy
Introduction: Cochlear implantation (CI) is now regarded as a standard treatment for children with severe to profound sensor neural hearing loss. This study aimed to compare the efficacy of the round window approach (RWA) and standard cochleostomy approach (SCA) in the preservation of residual hearing after CI in pediatric patients. Materials and Methods: This double-blind ran...
متن کاملComparison of achievement of educational objectives in prosthodontics department of Shahed Dental School according to approved 2001 and 2013 curricula
Background and Objective: The educational process will be useful if the goals for which they are attained are fulfilled during or after the course. The aim of this study was to evaluate the achievement of the educational goals of the Prosthodontics Department of Shahed Dental School in two curricula. Materials and Methods: This cross-sectional study evaluated two dental curricula using CIPP...
متن کاملHearing preservation and cochlear implants according to inner ear approach: multicentric evaluation.
INTRODUCTION Electroacoustic stimulation is an excellent option for people with residual hearing in the low frequencies, who obtain insufficient benefit with hearing aids. To be effective, the subject's residual hearing should be preserved during cochlear implant surgery. OBJECTIVES To evaluate the hearing preservation in patients that underwent implant placement and to compare the results in...
متن کامل