Influence of the ultimate torsion on the geometry of dental implants.

نویسندگان

  • Ana Beatriz V Teixeira
  • Gabriela B S P Beja
  • Antônio Carlos Shimano
  • Ana Paula Macedo
  • Nathalia Ferraz Oliscovicz
  • Andréa C dos Reis
چکیده

This study evaluated the profile of implants subjected to torsion test. Four types of implants (Conexão®) were analyzed: Master Porous (MP - external hexagon, cylindrical, double-porous surface implants; 11.5 X 3.75 mm), Master Screw (MS - external hexagon, cylindrical, machined implants; 11.5 X 3.75 mm), Conect Conic (CC - external hexagon, cylindrical, machined implants; 11.5 X 3.5 mm) and Master Conect AR (CA - internal hexagon, cylindrical, double-porous surface implants; 11.5 X 3.75 mm). The Nikon® model C profile projector was used for the analysis before and after torsion test with a Mackena® model MK-20XX digital torque meter. The measures analyzed in the profile of implants were: diameter and height of the platform, diameter of the screw/platform connection, angle of the screw/platform connection, external diameter, internal diameter, thread pitch, height and length of the thread. Statistical analysis was performed using ANOVA and Tukey test at 5% significance level. The torsion test caused a visible deformity on the external implant profile. There was a statistical difference among the implants before and after torsion (p<0.05) for the variables: platform diameter, platform height, diameter of the screw/platform connection and length. Changes were observed in platform height of CC and CA, fracture of CA implants, fracture of the MP and MS assembler/connectors, and internal thread stripping of CC. Thus, it was concluded that excessive or some unadvised torque by the manufacturer can lead to changes in different geometric measurements of implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biologic Width around Dental Implants: An Updated Review

Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...

متن کامل

Prediction of Temperature Distribution in the Hot Torsion Test Specimen

Hot torsion test (HTT) has extensively been used to analysis and physically model flow behavior and microstructure evolution of materials and alloys during hot deformation processes. In this test, the specimen geometry has a great influence in obtaining reliable test results. In this paper, the interaction of thermal-mechanical conditions and geometry of the HTT specimen was studied. The commer...

متن کامل

Adult Stem Cells Properties in Terms of Commitment, Aging and Biological Safety of Grit-Blasted and Acid-Etched Ti Dental Implants Surfaces

Titanium (Ti) is one of the most widely used biomaterials for manufacturing dental implants. The implant surface properties strongly influence osseointegration. The aim of the present study was to in vitro investigate the characteristics of Ti dental implants in terms of mutagenicity, hemocompatibility, biocompatibility, osteoinductivity and biological safety. The Ames test was used to test the...

متن کامل

Immediate loading in dental implants ( A literature review )

Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...

متن کامل

The Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs

  Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 24 3  شماره 

صفحات  -

تاریخ انتشار 2013