Anomalous Heat Flow and Its Correlation with Deuterium Flux in a Gas-loading Deuterium-palladium System

نویسندگان

  • J. Tian
  • B. Liu
چکیده

A special experimental device was designed to test the anomalous thermal effect of Pd with deuterium flux (Df ) caused by deuteron diffusion passing through a thin wall of a Pd tube under a D2 pressure difference across the Pd wall. It is found that the variation of the flux was the significant precursor of the anomalous heat, because a remarkable heat flow was detected when the Df was becoming obviously larger. The experiment was repeated for more than 16 times, and the maximum heat flow detected was 4.8mW whereas the accuracy of the calorimeter is better than 30μW. There were no heat flow detected when the temperature of the device was increased and when the D2 pressure difference equaled to zero. Neither heat flow nor flux was observed in the control experiment using N2.gas. The results of TLD (Themoluminescence dosimeter) detection implied a nuclear origin of the heat flow because the dosage of radiation in reaction vessel was often higher than that in reference vessel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between abnormal deuterium flux and heat flow in a D/Pd system

Deuterium flux through the thin wall of a palladium tube has been studied by monitoring gas pressure and temperature. A high-precision calorimeter (Calvet) was used to detect heat flow when the heater was shut down and the palladium tube was cooling down slowly. At certain temperatures an abnormal deuterium flux appeared. This deuterium flux reached a peak when the temperature of the palladium ...

متن کامل

Will, F

Highlights are presented of recent results obtained on deuterium and hydrogen loading of palladium both in electrolytes and in the gas phase. Reproducible tritium generation has been found on palladium cathodes with deuterium loadings approaching one deuterium atom per palladium atom. Tritium generation has been observed on four out of four such highly loaded cathodes. No tritium has been obser...

متن کامل

Electrochemical Loading of Hydrogen and Deuterium Into Palladium and Palladium-Boron Alloys

Excess power production and other anomalous effects have been observed during the electrolysis of heavy water using palladium and palladium-boron alloys as the cathode materials. This study focused on hydrogen and deuterium loading into palladium and palladium-boron alloys. Improved calorimetry provided for the detection of the exothermic heat of absorption of deuterium into palladium and palla...

متن کامل

Triggering A Deuterium Flux In Pd Wire Using Electromagnetic Field

An electromagnetic field is applied on a long-thin Pd wire to test the effect of an electrical potential on the loading of the deuterium gas into the palladium, which was proposed by Del Giudice, De Ninno and their group during ICCF-9. The preliminary experimental results showed that this electromagnetic field triggered not only the loading, but also the “excess heat” because of the deuterium f...

متن کامل

Hydrogen Absorption Property of Pd-Doped Porous Materials

In electrochemical loading of Pd with deuterium, it has been known that attaining a D/Pd value larger than 0.88 is necessary for triggering excess heat effects [1]. It has been reported by Arata and Zhang that the heat arising from D-D nuclear fusion reaction in solid is observed simply by pressurizing nano-Pd/ZrO2 system with deuterium gas [2]. It seems that nano-scale Pd particles absorb more...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005