Do echo-enhanced needles improve time to cannulate in a model of short-axis ultrasound-guided vascular access for a group of mostly inexperienced ultrasound users?

نویسندگان

  • Michael P. Phelan
  • Chuck Emerman
  • William F. Peacock
  • Mathew Karafa
  • Nora Colburn
  • Kelly Buchanan
چکیده

BACKGROUND Vascular access is a critical skill for emergency physicians. However, it can be unpredictably challenging in some patients. While ultrasound-guided vascular access has been encouraged in emergency departments, there have been few studies evaluating echo-enhanced needles and their usefulness in performing vascular access. AIMS Our purpose was to determine if the use of an echo-enhanced needle tip results in faster vascular access times, with fewer needle sticks, fewer redirections, and improved needle visualization in ultrasound-guided vascular access with the vessel in the short axis. METHODS This is a prospective, randomized, observational study of ultrasound-guided vascular access on a vascular phantom comparing an echo-enhanced needle with a standard needle. Each participant viewed a teaching video demonstrating typical ultrasound-guided vascular access and then attempted ultrasound-guided vascular access using both a standard and an echo-enhanced needle with the vessel in the short axis. The numbers of needle sticks, redirections, and time to dye flash were measured. RESULTS The 69 participants attempted 69 short-axis ultrasound-guided vascular cannulations with no difference in time to dye flash between needle types: the median time from needle stick to flash was 17.56 s [interquartile range (IQR): 12.37-33.15] for the standard needle and 19.22 s (IQR: 10.19-31.10) for the echo-enhanced needle. There was no difference between needle types for number of needle sticks or redirects. CONCLUSION Echo-enhanced needles did not provide objective performance improvement compared to standard needles during ultrasound-guided vascular access with a vascular access model in the short axis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echo-enhanced needles for short-axis ultrasound-guided vascular access

Dear Editors, I read with interest the study by Phelan et al. [1]. The authors should be commended for their study evaluating the use of echo-enhanced needles in obtaining ultrasoundguided vascular access using a short-axis view. Historically, ultrasound has been used to guide needle, catheter and guidewire placement by radiologists but it now is being used increasingly by anaesthesiologists, e...

متن کامل

Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach.

OBJECTIVES Ultrasound guidance for central venous catheterization improves success rates and decreases complications when compared to the landmark technique. Prior research has demonstrated that arterial and/or posterior vein wall puncture still occurs despite real-time ultrasound guidance. The inability to maintain visualization of the needle tip may contribute to these complications. This stu...

متن کامل

Do echo-enhanced needles make a difference in sonographically guided vascular access?

OBJECTIVES The purpose of this study was to compare sonographically guided vascular access using standard and echo-enhanced needles in a variety of tissue-simulating vascular phantoms. METHODS We conducted a prospective single-blinded observational study at an academic medical center. All participants performed real-time sonographically guided vascular access using both a standard 18-gauge ne...

متن کامل

The oblique view: an alternative approach for ultrasound-guided central line placement.

BACKGROUND Numerous studies have shown significant benefits of using real-time ultrasonography for central line intravenous access. Traditionally, the ultrasound probe is placed along the short axis of the vein to visualize and direct needle placement. This view has some limitations, particularly being able to visualize the needle tip. Some practitioners place the ultrasound probe in the long a...

متن کامل

Ultrasound-guided induced fetal death, an alternative method for induction of abortion in the bitch

This study was performed to achieve abortion in a short time and with minimum side effects in a bitch, as an alternative method for termination of unwanted pregnancy. The experimentation was performed on 10 privately owned crossbred pregnant bitches, in their late second trimester of pregnancy, having a variable number of fetuses (3 to 9). Fetal death was induced by transabdominal intracardiac ...