Geometry of Two-Slit Camera

نویسنده

  • Tomáš Pajdla
چکیده

We analyze the geometry of the two-slit camera and come to two conclusions. First, we show that the definition given by et al. [9] makes sense only if the two slits are not intersecting. Secondly, we prove that the complete image from a two-slit camera cannot be obtained as an intersection of the rays of the two-slit camera with a plane in space. Motivated by the quest for a unified representation of various cameras by simple geometrical objects, we give a new definition of linear oblique cameras as those which comprise all real lines incident with some non-real line and show that it is equivalent with the definition we gave earlier. We also show that no single line neither in the real projective space nor in its coplexification, can be used to define analogously a two-slit camera.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Derivation and validation of a sensitivity formula for knife-edge slit gamma camera: A theoretical and Monte Carlo simulation study

Introduction: Gamma cameras are proposed for online range verification and treatment monitoring in proton therapy.  An Analytical formula was derived and validated for sensitivity of a slit collimator based on the photon fluence concept. Methods: Fluence formulation was generalized for photons distribution function and solved for high-energy point sources. The...

متن کامل

Concentric Panorama Geometry

In this paper, the geometric relationship between mosaic images for concentric panorama acquired by slit cameras along circular paths is considered. A concentric epipolar constraint is derived for mosaic images. It is shown how the concentric epipolar constraint can be used to calibrate the slit camera using point correspondences in two mosaic images. The concentric epipolar constraint is furth...

متن کامل

A study on differentiation of extra-cardiac activity by Slit Slat collimation in Single Photon Emission Computed Tomography

Introduction: Myocardial perfusion SPECTby 99mTc-Sestamibi and 99mTc-Tetrofosmin radiopharmaceuticals usually presents a false significant increase in the radiotracer uptake in the inferior myocardium due to the uptake in organs such as liver, bowel, stomach and biliary system. The present study evaluated a suitable Slit angle for differentiating extra-car...

متن کامل

Feasibility of detecting and localizing radioactive source using image processing and computational geometry algorithms

We consider the problem of finding the localization of radioactive source by using data from a digital camera. In other words, the camera could help us to detect the direction of radioactive rays radiation. Therefore, the outcome could be used to command a robot to move toward the true direction to achieve the source. The process of camera data is performed by using image processing and computa...

متن کامل

A Range Finder by Using a Rotary Cubic Mirror

The slit light scanning method is a conventional method of range finder. But according to this method, it is impossible to measure the three dimensional shape when the object is too large, because camera is fixed against the observation field. In this paper, we propose a new active range finder with a rotary cubic mirror to solve these problems. In this sensing system, slit light and view of ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002