Thermal analysis of bulk filled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall

نویسندگان

  • Hoon-Sang CHANG
  • Kyu-Jeong CHO
  • Su-Jung PARK
  • Bin-Na LEE
  • Yun-Chan HWANG
  • Won-Mann OH
  • In-Nam HWANG
چکیده

OBJECTIVE The purpose of this study was to investigate the polymerization temperature of a bulk filled composite resin light-activated with various light curing modes using infrared thermography according to the curing depth and approximation to the cavity wall. MATERIAL AND METHODS Composite resin (AeliteFlo, Bisco, Schaumburg, IL, USA) was inserted into a Class II cavity prepared in the Teflon blocks and was cured with a LED light curing unit (Dr's Light, GoodDoctors Co., Seoul, Korea) using various light curing modes for 20 s. Polymerization temperature was measured with an infrared thermographic camera (Thermovision 900 SW/TE, Agema Infra-red Systems AB, Danderyd, Sweden) for 40 s at measurement spots adjacent to the cavity wall and in the middle of the cavity from the surface to a 4 mm depth. Data were analyzed according to the light curing modes with one-way ANOVA, and according to curing depth and approximation to the cavity wall with two-way ANOVA. RESULTS The peak polymerization temperature of the composite resin was not affected by the light curing modes. According to the curing depth, the peak polymerization temperature at the depth of 1 mm to 3 mm was significantly higher than that at the depth of 4 mm, and on the surface. The peak polymerization temperature of the spots in the middle of the cavity was higher than that measured in spots adjacent to the cavity wall. CONCLUSION In the photopolymerization of the composite resin, the temperature was higher in the middle of the cavity compared to the outer surface or at the internal walls of the prepared cavity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

µCT-3D visualization analysis of resin composite polymerization and dye penetration test of composite adaptation.

This study evaluated the effects of the light curing methods and resin composite composition on composite polymerization contraction behavior and resin composite adaptation to the cavity wall using μCT-3D visualization analysis and dye penetration test. Cylindrical cavities were restored using Clearfil tri-S Bond ND Quick adhesive and filled with Clearfil AP-X or Clearfil Photo Bright composite...

متن کامل

Effects of light curing method and resin composite composition on composite adaptation to the cavity wall.

This study aimed to evaluate the effects of the light curing method and resin composite composition on marginal sealing and resin composite adaptation to the cavity wall. Cylindrical cavities were prepared on the buccal or lingual cervical regions. The teeth were restored using Clearfil Liner Bond 2V adhesive system and filled with Clearfil Photo Bright or Palfique Estelite resin composite. The...

متن کامل

Environmental SEM and dye penetration observation on resin-tooth interface using different light curing method.

The aim of this study was the effects of different light curing methods on marginal sealing and resin composite adaptation to the cavity wall using the dye penetration test and environmental scanning electron microscope (SEM) observations. Cylindrical cavities were prepared on cervical regions. The teeth were restored with Clearfil Liner Bond 2 V adhesive and filled with Clearfil Photo Bright o...

متن کامل

Effect of Curing Time on Polymerization Rate of Bulk-Fill Composite Resins

Objectives: The aim of this study was to compare polymerization depth of two bulk-fill and one conventional composite cured for different times. Methods: This in vitro experimental study was conducted on 54 composite samples (2×4×10mm) fabricated of Tetric N-Ceram bulk-fill, x-tra fil bulk-fill, and Grandio conventional composite cured for 20, 30, and 40 seconds. The microhardnes...

متن کامل

Effect of Three Light Curing Protocols and Load Cycling on Microleakage of Class V Composite Restorations

  Objective: Different methods have been suggested to overcome the polymerization shrinkage of composite restorations. Changing the light curing protocol to improve polymerization by using new light curing units is among these methods. The new devices are more efficient, portable and durable and produce less heat. This study aimed to assess the marginal microleakage of class V composite restora...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2013