Modeling Compound Loss from Polydimethylsiloxane Passive Samplers
نویسندگان
چکیده
Volatile losses were measured from polydimethylsiloxane (PDMS) passive samplers during determination of contaminant porewater concentrations in sediments. Volatile losses could occur between the time of retrieval and processing of the passive sampler or in intertidal environments where the passive sampler could potentially be exposed above the water surface at low tide. A model was developed to predict losses of absorbed compounds as a function of sorbent geometry and the Henry’s Law Coefficient and PDMS-water partition coefficient of the compound of interest. The model suggests that thin layers of PDMS typically used to minimize equilibration times in passive sampling (≤30 μm) may not provide quantitative measurement of naphthalenes or other lighter volatile compounds without special efforts to reduce losses. The results suggest that the samplers should be processed rapidly onsite or kept at low temperatures after retrieval to maximize retention of more volatile compounds or designed with thick PDMS layers. The results also suggest that less volatile compounds, including phenanthrene, and higher molecular weight polynuclear aromatic hydrocarbons (PAHs) exhibit minimal evaporative losses with typical sample processing times.
منابع مشابه
Application of passive sampling for measuring dissolved concentrations of organic contaminants in the water column at three marine superfund sites.
Currently, there is an effort under way to encourage remedial project managers at contaminated sites to use passive sampling to collect freely dissolved concentrations (Cfree ) of hydrophobic organic contaminants to improve site assessments. The objective of the present study was to evaluate the use of passive sampling for measuring water column Cfree for several hydrophobic organic contaminant...
متن کاملGABIE and Perkin Elmer passive sampler performance under fluctuating concentration conditions.
Passive sampling is an approved and accurate method for the assessment of organic compound exposure over long sampling time. This method could be very convenient for the short-time exposure assessment, but passive samplers have to be validated for this use. In this article, the behaviour of two commercial passive samplers (GABIE and Perkin Elmer) under fluctuant concentration conditions is stud...
متن کاملGaseous Products of Incense Coil Combustion Extracted by Passive Solid Phase Microextraction Samplers
Burning incense indoors is a common behavior in Southeast Asia. In this investigation, needle trap samplers (NTS), a novel, green analytical technology is used for sampling gaseous combustion by-products from sandalwood incense coils. To extract indoor volatile organic compounds (VOCs), two NTS are prepared, one using 60–80 mesh and the other using 100–120 mesh divinylbenzene (DVB) particles pa...
متن کاملA Model Using Local Weather Data to Determine the Effective Sampling Volume for PCB Congeners Collected on Passive Air Samplers
We have developed and evaluated a mathematical model to determine the effective sampling volumes (Veff) of PCBs and similar compounds captured using polyurethane foam passive air samplers (PUF-PAS). We account for the variability in wind speed, air temperature, and equilibrium partitioning over the course of the deployment of the samplers. The model, provided as an annotated Matlab script, pred...
متن کاملA review of passive sampling systems for ambient air mercury measurements.
Atmospheric mercury (Hg) temporal and spatial patterns must be measured accurately in order to adequately understand the role of this pathway as it relates to Hg toxicity and exposure of humans and wildlife to Hg. It is also important to understand the distribution of the different chemical forms (elemental, oxidized, or particle bound) and specific compounds in air (e.g., HgCl2, HgBr2, HgO, Hg...
متن کامل