Intensity matters: Therapist-dependent dose of spinal transcutaneous electrical nerve stimulation

نویسندگان

  • Diego Serrano-Muñoz
  • Julio Gómez-Soriano
  • Elisabeth Bravo-Esteban
  • María Vázquez-Fariñas
  • Julian Taylor
  • Juan Avendaño-Coy
چکیده

The intensity used during transcutaneous electrical nerve stimulation (TENS) in both, clinical practice and research studies, is often based on subjective commands such as "strong but comfortable sensation". There is no consensus regarding the effectiveness dose of TENS. The objective was to determine the difference in the effect of spinal TENS on soleus H-reflex modulation when applied by two therapists instructed to apply the stimulation at a "strong but comfortable" intensity. Twenty healthy volunteers divided into two groups: Therapist 1 (n = 10) and Therapist 2 (n = 10). Both therapist applied spinal TENS and sham stimulation at the T10-12 spinal level for 40min in random order to each subject, at an intensity designed to produce a "strong but comfortable" sensation. To avoid habituation, the intensity was adjusted every 2min. Soleus H-reflex was recorded before, during, and 10min after TENS by an observer blinded to the stimulus applied. Despite the instruction to apply TENS at a "strong comfortable" level, a significant difference in current density was identified: Therapist 1 (0.67mA/cm2, SD 0.54) applied more than Therapist 2 (0.53mA/cm2, SD 0.57; p<0.001) at the onset of the intervention. Maximal peak-to-peak H-reflex amplitude was inhibited significantly more 10min following TENS applied by Therapist 1 (-0.15mV, SD 0.16) compared with Therapist 2 (0.04mV, SD 0.16; p = 0.03). Furthermore, current density significantly correlated with the inhibitory effect on peak-to-peak Soleus H-reflex amplitude 10 min after stimulation (Rho = -0.38; p = 0.04). TENS intensity dosage by the therapist based on the subjective perception of the participants alone is unreliable and requires objective standardization. In addition, higher current density TENS produced greater inhibition of the Soleus H-reflex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does High Frequency Transcutaneous Electrical Nerve Stimulation (TENS) Affect EEG Gamma Band Activity?

Background: Transcutaneous electrical nerve stimulation (TENS) is a noninvasive, inexpensive and safe analgesic technique used for relieving acute and chronic pain. However, despite all these advantages, there has been very little research into the therapeutic effects of TENS on brain activity. To the best of our knowledge, there is no evidence on the effect of high frequency TENS on the gamma ...

متن کامل

Comparative Use of Electromyography in the Evaluation of Electroacupuncture and Transcutaneous Electrical Neural Stimulation (TENS) Effect on Regeneration of Sciatic Nerve in Dog

Objective-To determine the effect of Electroacupuncture and Transcutaneous Electrical Neural Stimulation on Regeneration of Sciatic Nerve in Dog   Design - Experimental in vivo study. Animals - A total of 15 adult male mixed bred dogs, weighing 26±2.6 Kg/BW with aging of 42±6 months, which were divided into three groups of  5 dogs. Procedures-Under general anesthesia, the right sciatic nerv...

متن کامل

Effectiveness of Action Potential Simulation and Transcutaneous Electrical Nerve Stimulation on Pain and Function of Patients With Chronic Mechanical Shoulder Impairment

Purpose: Rehabilitation and physiotherapy have a major role in reducing the pain and increasing the functional ability in patients with shoulder joint pain. This study aimed to evaluate the effect of Action Potential Simulation (APS) and Transcutaneous Electrical Nerve Stimulation (TENS) in patients with Chronic Mechanical Shoulder Pain (CMSP).&nbsp; Methods: In this quasi-experimental stu...

متن کامل

The suppressive effect of electrical stimulation on nociceptive responses in the rat.

BACKGROUND AND PURPOSE The aim of this investigation was to study the effect of electrical stimulation on nociceptive responses within the lumbar levels of the rat spinal cord. METHODS A single high-energy thermal pulse produced by a surgical laser stimulator (5 W, 30 milliseconds) was applied on the plantar surface of the hind paws of male Sprague-Dawley rats. The spinal cord field potential...

متن کامل

Evidence for spinal cord hypersensitivity in chronic pain after whiplash injury and in fibromyalgia Pain, January 2004, Pages 7-15

FROM ABSTRACT: Patients with chronic pain after whiplash injury and fibromyalgia patients display exaggerated pain after sensory stimulation. Because evident tissue damage is usually lacking, this exaggerated pain perception could be explained by hyperexcitability of the central nervous system. The nociceptive withdrawal reflex (a spinal reflex) may be used to study the excitability state of sp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017