Applications of various imaging techniques in neutron radiography at BARC, Trombay
نویسنده
چکیده
Neutron radiography systems based on Gd, Dy and In metallic foils and X-ray films have been used at this centre since early seventies for various NDT and R&D work in nuclear, defense and aerospace industries. In recent years use of digital detection systems such as neutron scintillator and CCD based imaging systems and photostimulated luminescence based phosphor imaging plate systems have been introduced in our work. This has enabled to achieve higher sensitivities and dynamic ranges of recording radiographs with acceptable spatial resolution. These new systems provide digital image information and are more convenient for quantitative evaluations. At BARC these new techniques have been used in variety of radiography techniques such as conventional neutron radiography (NR), neutron induced beta radiography (NIBR), hydrogen sensitive epithermal neutron radiography (HYSEN) using Apsara, CIRUS and Dhruva reactors as neutron sources. The details of the work done are described in this paper.
منابع مشابه
Neutron crystallography – Then and now *
Neutron crystallography began to be employed at the Bhabha Atomic Research Centre (BARC), Trombay, Mumbai in the early sixties. At that time, the technique, at BARC as well as elsewhere, was in a nascent state, with emphasis on building of instruments and development of crystallography software. Over the years, the Trombay group kept pace with the advancements in other parts of world and employ...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملNeutron Radiography, Techniques and Applications
After describing the principles of the "in pool" and "dry" installations, techniques used in neutron radiography are reviewed. Use of converter foils with silver halide films for the direct and transfer methods is described. Advantages of the use of nitrocellulose film for radiographying radioactive objacts are discussed. Dynamic imaging is shortly reviewed. Standardization in the field of neut...
متن کاملAlkyl Chain Dynamics in Monolayer-Protected Clusters (MPCs): A Quasielastic Neutron-Scattering Investigation
S. Mitra,† Binoj Nair,‡ T. Pradeep,*,‡,⊥ P. S. Goyal,§ and R. Mukhopadhyay*,†,| Solid State Physics DiVision, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India, Department of Chemistry and Regional Sophisticated Instrumentation Centre, Indian Institute of Technology, Madras 600 036, India, and Inter-UniVersity Consortium for DAE facilities, BARC, Mumbai 400 085, India ReceiVed: Dece...
متن کاملAdvances in X-ray and Neutron Imaging and Its Applications
Neutrons and X-rays provide a means to peer into the interior of objects, which are otherwise not optically visible. With the development of detector technology and new radiation sources, several new imaging technologies using x-rays and neutrons have emerged and have found widespread applications in industry, material science and medical imaging. The last two decades have seen the development ...
متن کامل