Reliability and validity of high-frequency (8-20 kHz) thresholds obtained on a computer-based audiometer as compared to a documented laboratory system.
نویسندگان
چکیده
A Macintosh computer-based audiometer (Virtual 320) was evaluated for reliability and validity of high-frequency (8-20 kHz) thresholds by comparison with a well documented laboratory high-frequency evaluation system (PARVA-HF). High-frequency earphones originally provided with the V320 for high-frequency testing required modification to improve reliability in calibration and in subject threshold testing. Twenty normal-hearing adults were evaluated in the 8-20 kHz frequency range on both testing systems. Results of intrasubject multiple-session testing were evaluated to determine the reliability of high-frequency thresholds obtained. The V320 produced reliable results comparable to the PARVA-HF. Validity of high-frequency thresholds was inferred by comparing V320 responses to those obtained with the PARVA-HF. Comparable findings between systems imply validity of thresholds obtained with the V320. Conventional frequency (0.25-8 kHz) threshold evaluation with the V320 and a Grason-Stadler 1701 audiometer also yielded comparable results.
منابع مشابه
High-frequency audiometry in young and older adults when conventional audiometry is normal.
UNLABELLED High-frequency audiometry can detect early changes in auditory sensitivity resulting from processes such as aging. Nonetheless its use is still limited, and additional studies are required to establish its use, particularly among older adults. AIM To compare pure tone thresholds for frequencies from 250 Hz to 16 kHz in young and older adults, with or without audiologic complaints. ...
متن کاملValidity of diagnostic computer-based air and forehead bone conduction audiometry.
Computer-based audiometry allows for novel applications, including remote testing and automation, that may improve the accessibility and efficiency of hearing assessment in various clinical and occupational health settings. This study describes the validity of computer-based, diagnostic air and forehead bone conduction audiometry when compared wtih conventional industry standard audiometry in a...
متن کاملPure-tone audiometry outside a sound booth using earphone attentuation, integrated noise monitoring, and automation.
OBJECTIVE Accessibility of audiometry is hindered by the cost of sound booths and shortage of hearing health personnel. This study investigated the validity of an automated mobile diagnostic audiometer with increased attenuation and real-time noise monitoring for clinical testing outside a sound booth. DESIGN Attenuation characteristics and reference ambient noise levels for the computer-base...
متن کاملThe relationship between ultra-high frequency thresholds and transient evoked otoacoustic emissions in adults with tinnitus
Background: The possible role of cochlear function in tinnitus generation is still a matter of debate. To assess the role of outer hair cell dysfunction in tinnitus and its possible relationship with ultra-high frequency (UHF) hearing sensitivity, transient evoked otoacoustic emissions (TEOAE) and UHF hearing thresholds were investigated in normal hearing individuals with and withou...
متن کاملIntercontinental hearing assessment - a study in tele-audiology.
We evaluated the validity of remote pure tone audiometric testing conducted from North America on subjects in South Africa. Desktop-sharing computer software was used to control an audiometer in Pretoria from Dallas, and PC-based videoconferencing was employed for clinician and subject communication. Thirty adult subjects were assessed, and the pure tone audiometric thresholds (125-8000 Hz) obt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 1 3 شماره
صفحات -
تاریخ انتشار 1990