Reproducibility of hypercapnic ventilatory response measurements with steady-state and rebreathing methods
نویسندگان
چکیده
In this study, the hypercapnic ventilatory response (HCVR) was measured, defined as the ventilation response to carbon dioxide tension (PCO2 ). We investigated which method, rebreathing or steady-state, is most suitable for measurement of the HCVR in healthy subjects, primarily based on reproducibility. Secondary outcome parameters were subject experience and duration. 20 healthy adults performed a rebreathing and steady-state HCVR measurement on two separate days. Subject experience was assessed using numeric rating scales (NRS). The intraclass correlation coefficient (ICCs) of the sensitivity to carbon dioxide above the ventilatory recruitment threshold and the projected apnoea threshold were calculated to determine the reproducibility of both methods. The ICCs of sensitivity were 0.89 (rebreathing) and 0.56 (steady-state). The ICCs of the projected apnoea threshold were 0.84 (rebreathing) and 0.25 (steady-state). The steady-state measurement was preferred by 16 out of 20 subjects; the differences in NRS scores were small. The hypercapnic ventilatory response measured using the rebreathing setup provided reproducible results, while the steady-state method did not. This may be explained by high variability in end-tidal PCO2 . Differences in subject experience between the methods are small.
منابع مشابه
Sustained microgravity reduces the human ventilatory response to hypoxia but not to hypercapnia.
We measured the isocapnic hypoxic ventilatory response and the hypercapnic ventilatory response by using rebreathing techniques in five normal subjects (ages 37-47 yr) before, during, and after 16 days of exposure to microgravity (microG). Control measurements were performed with the subjects in the standing and supine postures. In both microG and in the supine position, the hypoxic ventilatory...
متن کاملReflex respiratory responses to progressive hyperoxic hypercapnia and normocapnic hypoxia in normocapnic and hypercapnic obstructive sleep apnea patients.
Ventilatory responses to progressive hypercapnia were analyzed in the normocapnic and hypercapnic obstructive sleep apnea patients (OSA). The rebreathing hypercapnic and hypoxic tests were performed using the computerized equipment (Lungtest, MES), according to Read's method. The ventilatory response to hypoxia was impaired in all OSA patients. Concerning the hypercapnic ventilatory response, t...
متن کاملInfluence of indomethacin on ventilatory and cerebrovascular responsiveness to CO2 and breathing stability: the influence of PCO2 gradients.
Indomethacin (INDO), a reversible cyclooxygenase inhibitor, is a useful tool for assessing the role of cerebrovascular reactivity on ventilatory control. Despite this, the effect of INDO on breathing stability during wakefulness has yet to be examined. Although the effect of reductions in cerebrovascular CO(2) reactivity on ventilatory CO(2) sensitivity is likely dependent upon the method used,...
متن کاملEffects of body position on the ventilatory response to hypercapnia
Effect of posture on the hypercapnic ventilatory response was studied on the anaesthetized rats by using rebreathing techniques in the supine and head-down positions. There were no statistically significant alterations in tidal volume, frequency, minute ventilation, and P(ET)CO(2)between the head-down and supine positions during breathing at rest. However, the esophageal pressure inspiratory sw...
متن کاملEffect of ventilatory settings on accuracy of cardiac output measurement using partial CO(2) rebreathing.
BACKGROUND Recently, a new device has been developed to measure cardiac output noninvasively using partial carbon dioxide (CO(2)) rebreathing. Because this technique uses CO(2) rebreathing, the authors suspected that ventilatory settings, such as tidal volume and ventilatory mode, would affect its accuracy: they conducted this study to investigate which parameters affect the accuracy of the mea...
متن کامل