Grazing-exit and micro X-ray fluorescence analyses for chemical microchips.
نویسندگان
چکیده
Grazing-exit x-ray fluorescence (GE-XRF) and micro x-ray fluorescence (micro-XRF) methods were applied to chemical microchips as a detection method. Since an energy-dispersive x-ray detector was used, the simultaneous detection of multiple elements was possible. An analyzing region was especially designed on the microchip so that a sample solution could be dried and concentrated in a suitable area corresponding to the size of the primary x-ray beam. Finally, it was confirmed that both analytical methods could be combined well for use with a microchip. In GE-XRF, the background intensity in the XRF spectrum was reduced at grazing-exit angles. In addition, a good relationship between the x-ray fluorescence intensities and the concentrations of standard solutions that were introduced into the microchip was obtained. This indicates that the GE-XRF method is feasible for trace elemental analysis in chemical microchip systems. In micro-XRF, an attempt was made to concentrate and dry the analyte within a small analyzing region. The preliminary results indicated that the micro-XRF method could be applied for the analysis of microchips.
منابع مشابه
Grazing-exit X-ray spectrometry for surface and thin-film analyses.
Electron-probe x-ray micro analysis (EPMA) and particle-induced x-ray emission analysis (PIXE) were performed under grazing-exit conditions. To control the exit angle (take-off angle), a new sample holder having a stepping motor was developed for grazing-exit EPMA. A carefully polished surface of a stainless-steal sample was measured. The surface of stainless steel is normally covered with a th...
متن کاملGrazing exit versus grazing incidence geometry for x-ray absorption near edge structure analysis of arsenic traces
In the presented study the grazing exit x-ray fluorescence was tested for its applicability to x-ray absorption near edge structure analysis of arsenic in droplet samples. The experimental results have been compared to the findings of former analyses of the same samples using a grazing incidence GI setup to compare the performance of both geometries. Furthermore, the investigations were accompl...
متن کاملSoft X-Ray Absorption Spectroscopy with Variable Surface Sensitivity using Fluorescence Yield Detection
Surface sensitivity in the soil X-ray absorption spectroscopy by the fluorescent X-ray yield detection under grazing exit condition is discussed. It is experimentally demonstrated at Si K-edge that the sampling depth can be controlled by changing exit angles in the vicinity of the critical angle for total reflection.
متن کاملNovel micro-reactor flow cell for investigation of model catalysts using in situ grazing-incidence X-ray scattering
The design, fabrication and performance of a novel and highly sensitive micro-reactor device for performing in situ grazing-incidence X-ray scattering experiments of model catalyst systems is presented. The design of the reaction chamber, etched in silicon on insulator (SIO), permits grazing-incidence small-angle X-ray scattering (GISAXS) in transmission through 10 µm-thick entrance and exit wi...
متن کاملX-ray fluorescence induced by standing waves in the grazing-incidence and grazing-exit modes: study of the Mg-Co-Zr system.
The characterization of Mg-Co-Zr tri-layer stacks using X-ray fluorescence induced by X-ray standing waves, in both the grazing-incidence (GI) and the grazing-exit (GE) modes, is presented. The introduction of a slit in the direction of the detector improves the angular resolution by a factor of two and significantly improves the sensitivity of the technique for the chemical characterization of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 21 7 شماره
صفحات -
تاریخ انتشار 2005