Palpebral position interdependence in blepharoptosis: comparison of the effect of instillation of 10% phenylephrine drop and digital lifting.

نویسندگان

  • Ivana Cardoso Pereira
  • Suzana Matayoshi
چکیده

PURPOSE To quantify and compare the effects of instillation with 10% phenylephrine and digital lifting on the contralateral upper eyelid of patients with involutional bilateral blepharoptosis. METHODS The present prospective clinical study involved patients with involutional bilateral blepharoptosis who underwent two tests: 1) digital lifting of the more ptotic eyelid and observation of the effect on the contralateral eyelid and 2) instillation of two drops of 10% phenylephrine in the more ptotic eye and observation of the effect on the contralateral eyelid. Patients were filmed before and 5, 10, and 15 min after instillation, and the resulting images were analyzed to obtain eyelid measurements. The results were tested using a linear mixed-effects model. RESULTS A total of 27 patients, ranging from 52 to 82 years of age (mean age 68.51 ± 8.21 years), 24 (88.88%) of whom were women, were included in the present study. In eyes that received instillation, the marginal distance reflex-1 (MDR1) values increased from baseline (1.21 ± 0.60 mm) until 10 min after instillation, then remained statistically unchanged until 15 min after instillation (2.42 ± 0.90 mm). Significant differences were observed in the contralateral eye of the group that underwent digital lifting (1.51 ± 0.53 mm - 1.63 ± 0.56 mm) and in the contralateral eye of the group that underwent 10% phenylephrine instillation (1.38 ± 0.54 mm - 1.63 ± 0.56 mm); p=0.02 and p<0.01, respectively. CONCLUSION In all eyes, 10% phenylephrine elevated the upper eyelid, with improved eyelid height at 10 min after instillation. Significant differences were observed in the height of the contralateral eyelid when compared before and after each intervention in each group; however, this difference was very small and nearly undetectable by conventional clinical evaluation in the digital lifting group. However, the 10% phenylephrine eye-drop test resulted in substantial changes in MDR1 values in the treated and contralateral eyes, indicating clinical and statistical efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی اثر قطره هوماتروپین 2% بر روی توپوگرافی قرنیه

 ABSTRACT The purpose of this study was the evaluation of cycloplegic effect of homatropine 2% on central corneal curvature and power. 43 volunteers who participated in the study were examined. Thirty-nine of them (28 men and 11 women) which had normal eyes with visual acuity of 20/20 and a mean age of 29.6 ± 6.7 years were selected. Then corneal topography was performed on both eyes. After per...

متن کامل

A cross-over study of the cycloplegic effects of a single topical application of cyclopentolate-phenylephrine and routine atropinization for 3.5 days.

Static refraction in children after the topical instillation of atropine twice a day during 3.5 days was compared with the refraction after a single instillation of one drop of 0.85% cyclopentolate + 1.5% phenylephrine in a randomized cross-over study. Atropine eye drops were applied by the parents at home, while the combination drop was applied by personnel at the eye clinic. Refraction was de...

متن کامل

The effect of patient positions, Sound production and neck rewind on Mallampati grading and classification to predict difficult mask ventilation in patients

 Aims and background: The difficulty of ventilation with masks is one of the most common causes of severe respiratory consequences in the field of anesthesia. Objective: To evaluate the effect of patient position, voice production and neck rejection on the Mallamapati grade, in order to predict the difficulty of ventilation with mask in patients. Materials and Methods: This research was of a pr...

متن کامل

Comparison of Prophylactic Infusion of Phenylephrine with Ephedrine for Prevention of Hypotension in Elective Cesarean Section under Spinal Anesthesi: A Randomized Clinical Trial

Background: Spinal anesthesia is an accepted technique in elective cesarean sections. However, hypotension, resulted from sympathectomy is a common problem, especially in pregnant women. Prevention of this complication by sympathomimetic agents is of potential clinical significance. The aim of this study is to compare the effect of prophylactic infusion of Phenylephrine versus Ephedrine in the ...

متن کامل

Comparison of Intravenous bolus Phenylephrine and Ephedrine in the Prevention of Post- spinal Hypotension during Cesarean Section

Abstract Introduction: Spinal anesthesia is a commonly used anesthetic technique for cesarean section. The hypotension is the serious and common complication for it. Prevention of this complication is an important challenge for anesthesiologists. Objective: The aim of this study is to compare the effect of prophylactic bolus injection of Phenylephrine and Ephedrine in the prevention of hypote...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arquivos brasileiros de oftalmologia

دوره 77 6  شماره 

صفحات  -

تاریخ انتشار 2014