High Energy BSE/SE/STEM Imaging of 8 um Thick Semiconductor Interconnects
نویسنده
چکیده
High energy (100-400 keV) scanning electron microscope (SEM) imaging of samples can be performed in the transmission electron microscope (TEM)/scanning TEM (STEM) when the system has secondary electron (SE) and/or backscattered (BSE) electron detector(s) installed. Previously, very high resolution SE imaging has been demonstrated at 200 keV in a STEM with a spherical aberration corrected condenser lens [1]. Additionally, imaging of semiconductor Cu interconnects in SiO2 dielectric located at distances > 3um below the surface has been accomplished using incident beam energies of 100-400 keV and a backscattered electron (BSE) detector [2]. In the high energy BSE analysis case, multilevel Cu interconnects are ideal structures to study because: 1) there is a large BSE yield difference between Cu and SiO2 so Cu can be easily detected and 2) Cu lines exist at multiple levels below the surface so multiple structures can be seen from different depths in one BSE image. In this paper, a semiconductor chip with 9 interconnect levels spanning 8 um in height was studied using SE, BSE and STEM imaging at incident beam energies of 300-400 keV in order to understand image content and quality versus the depth of the structure below the surface.
منابع مشابه
Quantitative Scanning Electron Microscopy of Surfaces
The emissive modes of secondary and backscattered electrons in a scanning electron microscope work more quantitavely for material and topographic contrasts and can better separate different types of contrast when using a multi-detector system. The detector system of conventional scanning electron microscopes often do not make the best use of the potentialities given by the electronspecimen inte...
متن کاملA New Microstructural Imaging Approach through EBSD Pattern Region of Interest Analysis
The requirements of a highly tilted sample and a well-polished surface for optimal EBSD pattern collection can make traditional SEM imaging challenging. With a tilted sample, SEM SE and BSE detectors are often in non-optimal positions for electron detection. For many materials, the polished surfaces produce weak contrast with SE imaging. Traditionally placed BSE detectors must be used with care...
متن کاملCement lines of secondary osteons in human bone are not mineral-deficient: new data in a historical perspective.
Using qualitative backscattered electron (BSE) imaging and quantitative energy dispersive X-ray (EDX) spectroscopy, some investigators have concluded that cement (reversal) lines located at the periphery of secondary osteons are poorly mineralized viscous interfaces with respect to surrounding bone. This conclusion contradicts historical observations of apparent highly mineralized (or collagen-...
متن کامل160 Milliohm Thru-Wafer Interconnects with 10:1 Aspect Ratio
We present a novel approach for high-aspect ratio low resistance Thru-Wafer Interconnects for DoubleSided (TWIDS) fabrication of MicroElectroMechanical Systems (MEMS). The interconnects are formed by etching blind via holes in the handle substrate of an SOI (Silicon on Insulator) wafer, followed by filling the holes with copper, using sonic-assisted seedless copper electroplating process. This ...
متن کاملDual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.
Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the ef...
متن کامل