Allergen microarrays on high-sensitivity silicon slides.
نویسندگان
چکیده
We have recently introduced a silicon substrate for high-sensitivity microarrays, coated with a functional polymer named copoly(DMA-NAS-MAPS). The silicon dioxide thickness has been optimized to produce a fluorescence intensification due to the optical constructive interference between the incident and reflected lights of the fluorescent radiation. The polymeric coating efficiently suppresses aspecific interaction, making the low background a distinctive feature of these slides. Here, we used the new silicon microarray substrate for allergy diagnosis, in the detection of specific IgE in serum samples of subjects with sensitizations to inhalant allergens. We compared the performance of silicon versus glass substrates. Reproducibility data were measured. Moreover, receiver-operating characteristic (ROC) curves were plotted to discriminate between the allergy and no allergy status in 30 well-characterized serum samples. We found that reproducibility of the microarray on glass supports was not different from available data on allergen arrays, whereas the reproducibility on the silicon substrate was consistently better than on glass. Moreover, silicon significantly enhanced the performance of the allergen microarray as compared to glass in accurately identifying allergic patients spanning a wide range of specific IgE titers to the considered allergens.
منابع مشابه
Breakthrough Technologies Direct Detection of Transcription Factors in Cotyledons during Seedling Development Using Sensitive Silicon-Substrate Photonic Crystal Protein Arrays
Transcription factors control important gene networks, altering the expression of a wide variety of genes, including those of agronomic importance, despite often being expressed at low levels. Detecting transcription factor proteins is difficult, because current high-throughput methods may not be sensitive enough. One-dimensional, silicon-substrate photonic crystal (PC) arrays provide an altern...
متن کاملDirect detection of transcription factors in cotyledons during seedling development using sensitive silicon-substrate photonic crystal protein arrays.
Transcription factors control important gene networks, altering the expression of a wide variety of genes, including those of agronomic importance, despite often being expressed at low levels. Detecting transcription factor proteins is difficult, because current high-throughput methods may not be sensitive enough. One-dimensional, silicon-substrate photonic crystal (PC) arrays provide an altern...
متن کاملAn Efficient Covalent Coating on Glass Slides for Preparation of Optical Oligonucleotide Microarrays
Objective(s): Microarrays are potential analyzing tools for genomics and proteomics researches, which is in needed of suitable substrate for coating and also hybridization of biomolecules. Materials and Methods: In this research, a thin film of oxidized agarose was prepared on the glass slides which previously coated with poly-L-lysine (PLL). Some of the aldehyde groups of the activated aga...
متن کاملDesign and Analysis of Comparative Microarray Experiments
This chapter discusses the design and analysis of relatively simple comparative experiments involving microarrays. Some of the discussion applies to all the most widely used kinds of microarrays, that is, radiolabelled cDNA arrays on nylon membranes, two-color, fluorescently labeled cDNA or long oligonucleotide arrays on glass slides, or single color, fluorescently labeled, high-density short o...
متن کاملMicroarrays for the screening of allergen-specific IgE in human serum.
The described in vitro test system for allergy diagnosis is based on microscope glass slides activated with (3-glycidyloxypropyl)trimethoxysilane. Allergen solutions are immobilized as small droplets (approximately 10 nL) on the activated glass slides with a piezoelectric arrayer. In contrast to other tests for specific IgE, such as Pharmacia CAP FEIA, AlaSTAT, or FAST, only a 25-microL serum s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical and bioanalytical chemistry
دوره 398 4 شماره
صفحات -
تاریخ انتشار 2010