Determination of parotid urea secretion in sheep by means of ultrasonic flow probes and a multifactorial regression analysis.

نویسندگان

  • A Cirio
  • F Méot
  • M L Delignette-Muller
  • R Boivin
چکیده

For determination of the dynamics of parotid urea secretion in conscious sheep, a previously standardized transit time ultrasonic flow metering system was used to measure bilateral parotid flow. Six ewes fed for ad libitum consumption were prepared under halothane anesthesia with ultrasonic probes around both parotid ducts; these ducts were also cannulated orally. After probe encapsulation (8 d), parotid flows were recorded during 24 h, and samples of saliva and blood for urea determination were obtained hourly. Jaw movements were recorded by means of a submandibular balloon to monitor feeding behavior. Urea concentration in parotid saliva was 60 to 74% of that in plasma (a positive linear correlation existed) and was poorly influenced by the parotid flow. The amount of urea secreted with parotid saliva was directly related to the salivation rate. To calculate the urea secretion in parotid saliva, a multiple linear regression model was developed from computer-calculated parotid flows over 1-min periods and plasma urea concentration. The model was accurate because the plot of calculated vs measured values was not significantly different from the line of identity. The daily parotid urea N varied from .35 to 1.02 g among ewes. The higher urea secretion rate found during rumination and eating (1.32+/-.42 and .98 +/-.33 mg/min, respectively) vs. during rest (.60+/-.39 mg/ min, P<.05) was due to higher salivation rates (5.17 +/-1.46, 3.56+/-.90, and 2.04+/-.52 mL/min, respectively, P<.05) rather than to changes in saliva urea concentrations (saliva:plasma urea ratio = .65+/-.04, .67+/-.04, and .68+/-.03, respectively). Of the daily parotid urea output, 40.8% was secreted during rest. The contribution of parotid urea N to the ruminal N pool was relatively small (1.2 to 3.7% of the N intake, which was 23.0 to 33.6 g/d). These techniques allowed direct and precise measurements of parotid urea secretion without disturbing the animal or altering the physiological regulation of salivary secretion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of renal handling of marbofloxacin in Lohi sheep (Ovis aries) following a single intravenous administration

The objective of present study was to investigate renal clearance, urinary excretion and underlying excretory mechanism of marbofloxacin in Lohi sheep. For this purpose, marbofloxacin was administered intravenously (IV) as single bolus dose (2.5 mg/kg body weight) to eight healthy sheep of Lohi breed. After start of experiment, blood and urine samples were drawn at predetermined time intervals ...

متن کامل

Intraruminal injection of urea and changes in secretion of parotid saliva in sheep.

1. Sheep were injected with varying doses of urea into the rumen and changes in the amount of saliva secreted from one parotid gland were studied. When the dose of urea was 0.1-0.2 g/kg, the secretion underwent no change. When the dose was 0.3 g/kg, the secretion was inhibited. When the dose was 0.4 or 0.5 g/kg, there was a marked inhibition in the secretion. 2. There was a close relationship b...

متن کامل

Technical note: measuring portal blood flow in sheep using an ultrasonic transit time flow probe.

Our objective was to validate the use of an ultrasonic transit-time flowmeter for the measurement of portal blood flow (PBF) in sheep. Data recorded with this technique were compared with those obtained with an indicator dilution method, and probes were calibrated in vivo. Wethers were fitted with catheters in the portal, jejunal, and ruminal veins and in a mesenteric artery. Ultrasonic flow pr...

متن کامل

Role of ultrasound probes in transmission of hospital infections

Background: The ultrasonography probes are cleaned by absorbent soft, dry cloth. This question arose whether linear and convex ultrasound probes coupling with gel could perform as a means for nosocomial infections transmission, and which method is economical and more efficient for cleaning the probes. This study was conducted to answer these questions. Methods: One hundred – ninety two patients...

متن کامل

Dispersive liquid-liquid microextraction using silver nanoparticles as electrostatic probes for preconcentartion and quantitative analysis of terazosin

An efficient dispersive liquid-liquid microextraction using tetraalkylammonium bromide coated silver nanoparticles (DLLME-AgNPs) prepared in chloroform has been successfully applied as electrostatic affinity probes to the microextraction and preconcentration of terazosin prior to spectrofluorimetry analysis. This technique is based on a ternary system of solvents, where appropriate amount of mi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 78 2  شماره 

صفحات  -

تاریخ انتشار 2000