Does digital flat detector technology tip the scale towards better image quality or reduced patient dose in interventional cardiology?

نویسندگان

  • E Bogaert
  • K Bacher
  • R Lapere
  • H Thierens
چکیده

As dynamic flat-panel detectors (FD) are introduced in interventional cardiology (IC), the relation between patient dose and image quality (IQ) needs to be reconsidered for this type of image receptor. On one hand this study investigates IQ of a FD system by means of a threshold contrast-detail analysis and compares it to an image intensifier (II) system on a similar X-ray setup. On the other hand patient dose for coronary angiography (CA) procedures on both systems is compared by Dose-Area Product (DAP)-registration of a patient population. The comparative IQ study was performed for a range of entrance dose rates (EDR) covering the fluoroscopy and cinegraphy working mode. In addition the IQ investigation was extended to a similar study under automatic brightness control (ABC). As well the systematic study of IQ as a function of EDR as the study performed under ABC point to a better IQ for FD in cinegraphy mode and no difference between both systems in fluoroscopy mode. The patient population study resulted in mean DAP values of 31Gycm(2) (II system) and 33Gycm(2) (FD system) (p=0.68) for CA procedures. As well total DAP as contributions of fluoroscopy and cinegraphy on both systems are not significantly different. To conclude, we could state that profit was taken from the intrinsic better performance of the FD for cinegraphy mode in producing higher quality images in this mode but without any effect on patient dose for CA procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flat detector versus image intensifier in cardiology. Why are patient doses initially higher?

Our purpose in this paper is to study the differences in patient doses imparted using dynamic flat detectors (FD) as opposed to using image intensifier (II) technology for interventional cardiology within two different European Centres, and then analyse the reasons for such differences. Several x-ray systems from two different manufacturers equipped with FDs ands IIs were used over the last 4 y...

متن کامل

Novel X-ray image noise reduction technology reduces patient radiation dose while maintaining image quality in coronary angiography

AIMS The consequences of high radiation dose for patient and staff demand constant improvements in X-ray dose reduction technology. This study assessed non-inferiority of image quality and quantified patient dose reduction in interventional cardiology for an anatomy-specific optimised cine acquisition chain combined with advanced real-time image noise reduction algorithms referred to as 'study ...

متن کامل

Quality comparison of direct digital panoramic radiography and computed radiography panoramic

BACKGROUND AND AIM: Digital panoramic X-ray images can be captured using photostimulable phosphors or solid-state detectors (i.e. charge-coupled devices and Flat-Panels). The first category is defined as computed radiography (CR) or semi-direct radiography. The second technology that uses solid-state detectors is known as direct digital radiography (DDR). Both of these technologies have their o...

متن کامل

Patient dose values during interventional cardiology examinations in Yazd hospital, Iran

Background: The number of interventional cardiology (IC) procedures has increased rapidly. coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) are now widely performed as a matter of routine, and they are considered safe procedures for experienced cardiologists. However, it is also known that these procedures are associated with high radiation doses due to long f...

متن کامل

Evaluation of the Influence of Exposure Index on Image Quality and Radiation Dose

Introduction: The introduction of digital radiography has led to a significant problem in terms of dose creep. To address this problem, manufacturers have established a set of exposure indicators (EI) as a feedback mechanism to safeguard against overexposure. The EI is the measure of incident exposure to the detector that is directly proportional to the signal-to-noise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of radiology

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2009