Two-dimensional glenoid version measurements vary with coronal and sagittal scapular rotation.

نویسندگان

  • Chris D Bryce
  • Andrew C Davison
  • Gregory S Lewis
  • Li Wang
  • Donald J Flemming
  • April D Armstrong
چکیده

BACKGROUND Accurate analysis of osseous glenoid morphology is important in treating glenohumeral arthritis and instability. Two-dimensional computed tomography scans are used to evaluate glenoid alignment. Accuracy of this method is dependent on the angle of axial reconstruction in relation to the position of the scapula. The purpose of this study was to investigate the effect of scapular rotation in the coronal and sagittal planes on glenoid version as measured on two-dimensional images. METHODS Computer-generated three-dimensional models of scapulae from computed tomography scans of thirty-six shoulders in whole-body cadavers were generated. The anatomic geometry of these models had been previously validated. The position of the scapulae relative to the gantry was determined. The three-dimensional models were rotated in 1 degree increments in the coronal and sagittal planes. Glenoid version was measured on two-dimensional images for each of the rotation increments. Version variability at each rotation increment was calculated. RESULTS The anatomic glenoid version (independent of the resting position of the scapula) was an average (and standard deviation) of 2.0 degrees +/- 3.8 degrees of retroversion. The average difference between anatomic glenoid version and clinical glenoid version (depending on the position of the scapula on the original computed tomography axial images) was 6.9 degrees +/- 5.6 degrees (range, 0.1 degrees to 22.5 degrees). Version variability with coronal or sagittal rotation was significant for all degrees of rotation (p < 0.0001). Scapular abduction had the greatest effect on version variation and resulted in 0.42 degrees of relative anteversion for every 1 degree of abduction in the coronal plane. In the sagittal plane, internal rotation resulted in relative anteversion. CONCLUSIONS Any malalignment of > or = 1 degree of the scapula in the coronal or sagittal plane will create inaccuracies in measuring glenoid version. The plane of axial reconstruction should be aligned with the scapula when two-dimensional computed tomography images are used to measure glenoid version. These findings support the use of three-dimensional models to evaluate glenoid version.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تاثیر سطوح حرکتی فرونتال، ساجیتال و اسکاپولا برمیزان چرخش بالایی کتف و نسبت به ریتم اسکاپولا

Backgroundm: Scapulohumeral rhythm (SHR) has been established as the kinematic hallmark indicating motion of the shoulder joint. Numerous studies have investigated the effect of different factors on SHR. The purpose of the present study was to determine the scapular upward rotation and scapulohumeral rhythm ratio among frontal, sagittal, and scapular planes in different humeral abduction ang...

متن کامل

Study of the variability of scapular inclination and the glenoid version - considerations for preoperative planning: clinical-radiological study

BACKGROUND Preoperative planning with the aid of imaging methods is a principal factor in successful surgery on the shoulder. This work aims to evaluate the variability of glenoid version, spiralling twist and scapular inclination in relation to the frontal axis. Studies focusing on measuring the variability of scapular inclination in the standardised rest position are lacking in the literature...

متن کامل

The Sprengel deformity. Morphometric analysis using 3D-CT and its clinical relevance.

We evaluated scapular dysplasia and malposition in 15 patients with the Sprengel deformity using three-dimensional CT (3D-CT). The shape, height-to-width ratio, the areas of both scapulae, the anterior curvature of the supraspinous portion and glenoid version were assessed on scapular posterior, medial and inferior views. The degree of rotation and superior displacement were measured on the tru...

متن کامل

Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty.

BACKGROUND/HYPOTHESIS The arthritic glenoid is typically in retroversion and restoration to neutral version is recommended. While a method for measurement of glenoid version using axial computed tomography (CT) has been reported and has been widely accepted, its accuracy and reproducibility has not been established. METHODS In 33 patients scheduled for shoulder arthroplasty, glenoid version a...

متن کامل

Accuracy of the Subchondral Smile and Surface Referencing Techniques in Reverse Shoulder Arthroplasty.

Inferior glenoid baseplate tilt relative to the coronal axis of the scapular body has been associated with improved results and fewer postoperative complications in reverse shoulder arthroplasty. However, the native glenoid surface is not always a reliable reference for the true scapular axis. Digital preoperative planning software and advanced imaging now allow surgeons to more precisely deter...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 92 3  شماره 

صفحات  -

تاریخ انتشار 2010