Failed valve-in-valve transcatheter aortic valve implantation.

نویسندگان

  • Stefan Klotz
  • Michael Scharfschwerdt
  • Doreen Richardt
  • Hans H Sievers
چکیده

c 2 a k o f d t 0 In 2004, a 68-year-old man received aortocoronary bypass surgery and a 23-mm Hancock porcine bioprosthesis (Medtronic, Minneapolis, Minnesota). Six years later, in January 2011, cardiac re-evaluation was performed due to progressive dyspnea. Invasive angiography showed open bypass grafts and severe stenosis of the porcine aortic bioprosthesis. Due to significant comorbidities, a 23-mm Sapien XT (Edwards Lifesciences, Irvine, California) transcatheter aortic valve (TAVI) was implanted as valve-in-valve. The procedure was uneventful. Initial angiography and echocardiography showed a good function of the valve with no insufficiency and a mean gradient of 20 mm Hg (Online Video 1). In March 2011, 3 months after the procedure, the patient was readmitted with cardiac decompensation. Reangiography showed open bypass grafts, but an invasive gradient of 50 mm Hg over the Sapien valve. Echocardiography confirmed the severe stenosis of the Sapien valve with a maximum gradient of 66 mm Hg, a mean of 43 mm Hg, and a valve opening area of 0.6 cm. Due to the severe dyspnea, reoperation was cheduled after recompensation. In May 2011, oth the Sapien valve and the 2004 implanted ancock bioprosthesis was explanted (Fig. 1) nd replaced with a 21-mm Trifecta (St. Jude edical, Inc., St. Paul, Minnesota) bioprostheis. The post-operative course was uneventful. Post-explantation assessment of the valves howed the implanted 23-mm Sapien valve in-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)

Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...

متن کامل

Transcatheter Aortic Valve Replacement: A Review Article

Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...

متن کامل

Transcatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves.

Most surgical heart valves currently implanted are bioprosthetic tissue valves. Such valves deteriorate with time, eventually presenting with either stenosis or regurgitation. Reoperation, the current standard of care for failed valves, carries significant risk in terms of both morbidity and mortality. Implantation of a transcatheter valve inside a failed surgical valve (valve-in-valve procedur...

متن کامل

Transcatheter Aortic and Mitral Valve-in-Valve Implantation for Failed Surgical Bioprosthetic Valves: An 8-Year Single-Center Experience.

OBJECTIVES We report our 8-year experience in transcatheter aortic and mitral valve-in-valve (VinV) implantation. BACKGROUND Feasibility and good early outcomes associated with transcatheter aortic and mitral VinV implantation into failed surgical bioprostheses have been confirmed, but the mid-term and long-term outcomes of transcatheter aortic and mitral VinV is unknown. METHODS A total of...

متن کامل

Transcatheter valve-in-valve implantation for failed surgical bioprosthetic valves.

When bioprosthetic cardiac valves fail, reoperative valve replacement carries a higher risk of morbidity and mortality compared with initial valve replacement. Transcatheter heart valve implantation may be a viable alternative to surgical aortic valve replacement for high-risk patients with native aortic stenosis, and valve-in-valve (V-in-V) implantation has been successfully performed for fail...

متن کامل

A permanent solution for a temporary problem: transcatheter valve-in-valve implantation for failed transcatheter aortic valve replacement.

Over the past decade, transcatheter aortic valve replacement (TAVR) matured from an adventitious endeavor in the early years to an established and paradigm-changing treatment option for many patients with severe aortic valve stenosis. However, lack of long-term data on device performance as well as the obvious presence of procedure-specific complications currently limit the expansion of this te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 5 5  شماره 

صفحات  -

تاریخ انتشار 2012