Postanesthesia patients with large upper arm circumference: is use of an "extra-long" adult cuff or forearm cuff placement accurate?
نویسندگان
چکیده
The purpose of this study was to determine if blood pressure (BP) measured in the forearm or with an extra-long BP cuff in the upper arm accurately reflects BP measured in the upper arm with an appropriately sized BP cuff in patients with large upper arm circumference. A method-comparison design was used with a convenience sample of 49 PACU patients. Noninvasive blood pressures were obtained in two different locations (forearm; upper arm) and in the upper arm with an extra-long adult and recommended large adult cuff sizes. Data were analyzed by calculating bias and precision for the BP cuff size and location and Student's t-tests, with P < .0125 considered significant. Significantly higher forearm systolic (P < .0001) and diastolic (P < .0002) BP measurements were found compared to BP obtained in the upper arm with the reference standard BP cuff. Significantly higher systolic (t(48df) = 5.38, P < .0001), but not diastolic (t(48df) = 4.11, P < .019), BP differences were found for BP measured with the extra-long cuff at the upper arm site compared to the upper arm, reference standard BP. Findings suggest that the clinical practice of using the forearm or an extra-long cuff in the upper arm for BP measurement in post anesthesia patients with large upper arm circumferences may result in inaccurate BP values.
منابع مشابه
Which cuff should I use? Indirect blood pressure measurement for the diagnosis of hypertension in patients with obesity: a diagnostic accuracy review
OBJECTIVE To determine the diagnostic accuracy of different methods of blood pressure (BP) measurement compared with reference standards for the diagnosis of hypertension in patients with obesity with a large arm circumference. DESIGN Systematic review with meta-analysis with hierarchical summary receiver operating characteristic models. Bland-Altman analyses where individual patient data wer...
متن کاملبررسی دقت اندازهگیری فشار خون از طریق ساعد با استفاده از نبض رادیال
Introduction: Blood pressure measurement (BPM) is the most common useful part of physical examination and patient assessment. And almost all physician and most of nurses use it for this mean. There are several methods for BPM and the most usefully of them is the standard method, by use of stethoscope and sphygmomanometer via brachial artery. When the upper arm (area from shoulder to elbow) is...
متن کاملWhat to do when faced with an unmeasurable ambulatory blood pressure?
If ambulatory blood pressure measurement is not possible because the upper-arm circumference is so great that even the largest cuff provided with the monitor will not encircle the arm, satisfactory measurements can be obtained by applying a cuff to the forearm.
متن کاملBlood pressure measurement in obese patients.
cialist in critical care, neurosciences, and bariatric surgery at Huntington Hospital in Pasadena, California. from a practical standpoint, is that the arms of obese people are no longer than the arms of nonobese persons of a similar height. Because of this discrepancy, following the standard for selecting cuff size results in a poor fit. Additionally many people who are obese have arms that ar...
متن کاملArm cuff in the measurement of blood pressure.
Selection of an arm cuff of the right size is necessary for accurate measurement of blood pressure (BP). Incorrect measurement can result either in unnecessary investigations, treatment, and follow-up for the mistaken diagnosis of hypertension, or no treatment for hypertension in individuals mistakenly thought to have normal BP. This is of particular importance in children, who have age-depende...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of perianesthesia nursing : official journal of the American Society of PeriAnesthesia Nurses
دوره 26 3 شماره
صفحات -
تاریخ انتشار 2011