Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma

نویسندگان

  • Lingyan Cheng
  • Yuzhi Ding
  • Xuanchu Duan
  • Zhifeng Wu
چکیده

The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA measured by DCT is an independent predictor for glaucoma diagnosis. A total of 217 eyes of 217 participants in the following five groups were included in this cross-sectional study: Chronic angle closure glaucoma (CACG), primary open angle glaucoma, normal tension glaucoma (NTG), suspected open angle glaucoma (SOAG) and normal control (NC). The following tests were simultaneously performed during a single visit: Intra-ocular pressure (IOP), OPA, cup-to-disk (C/D) ratio, mean damage (MD) and loss variance (LV). OPAs were compared in each group. The association between OPA and IOP, age, C/D ratio, MD and LV was detected. OPA analysis prior to and after trabeculectomy was also performed to assess its prognostic value. Among the 217 individuals, the OPA was consistent with the IOP, both measured by DCT, along with the MD and LV. Patients with CACG and SOAG had higher OPA values than those with NTG and normal controls. Compared with patients aged >30 years, the OPA was significantly lower in younger patients, while they may not have been affected by different C/D ratios. After trabeculectomy, the OPA had significantly decreased compared with the values prior to surgery. In conclusion, the present study showed that the OPA is correlated with the IOP determined by DCT. CACG and SOAG patients had higher OPA values than patients with other types of glaucoma. OPA measured by DCT may be a predictor for glaucoma diagnosis and prognosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.

PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...

متن کامل

Can dynamic contour tonometry and ocular pulse amplitude help to detect severe cardiovascular pathologies?

We demonstrate the close relationship between a conspicuous ocular pulse amplitude and severe underlying cardiovascular disease. Two otherwise symptom-free glaucoma patients without any previously diagnosed underlying cardiovascular pathology but with a conspicuous ocular pulse amplitude and who underwent routine examinations in our glaucoma department were referred to the appropriate specialty...

متن کامل

Dynamic contour tonometry in asymmetric glaucoma patients

BACKGROUND The purpose of this study was to determine any difference in dynamic contour tonometry and ocular pulse amplitude in asymmetric glaucoma patients with the same applanation intraocular pressure. METHODS This is a prospective, observational study of 30 glaucoma patients and 11 controls from June 2007 to February 2008. Most of the glaucoma patients were on prostaglandin analog treatme...

متن کامل

Comparison of Ocular Pulse Amplitude Lowering Effects of Preservative-Free Tafluprost and Preservative-Free Dorzolamide-Timolol Fixed Combination Eyedrops

PURPOSE To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. METHODS In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafl...

متن کامل

Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

BACKGROUND The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017