Prosthetic replacement of the ascending aorta increases wall tension in the residual aorta.
نویسندگان
چکیده
BACKGROUND Prosthetic replacement of the ascending aorta with nonelastic vascular grafts impairs the local Windkessel function. Whether this increases wall tension in the remaining aorta is still a not completely investigated hypothesis but is of clinical relevance with respect to postprocedural development of aneurysms and dissections, especially in the proximal descending aorta. METHODS Fresh porcine thoracic aortas, including the root, were set up in a mock circulation before and after prosthetic replacement of the ascending aorta. Cyclic changes in aortic dimensions were measured by ultrasonic micrometers at defined positions at the proximal part of the descending aorta. At the same positions, aortic pressures were recorded simultaneously using Millar tip manometers. Wall thickness was measured after pulsatile testing, and the resulting wall tension was calculated from the Laplace law. RESULTS After prosthetic replacement of the ascending aorta, peak systolic pressure in the proximal descending aorta increased from 117.6 +/- 6.1 mm Hg to 129.2 +/- 6.3 mm Hg, resulting in a rise of wall tension by 12.4% +/- 4.2% (p = 0.001). The maximum rate of pressure rise (dp/dt(max)) increased by 42.6% +/- 16.4% (p < 0.001). CONCLUSIONS Replacement of the ascending aorta with noncompliant prosthetic material significantly increases wall tension and rate of pressure rise in the residual aorta. This may have clinical impact with respect to a sudden and sustained rise of mechanical load, especially at the vulnerable proximal descending aorta.
منابع مشابه
In vitro investigation of a novel elastic vascular prosthesis for valve-sparing aortic root and ascending aorta replacement.
OBJECTIVES Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. METHODS Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular pros...
متن کاملModified ‘candy-plug’ technique for chronic type B aortic dissection with aneurysmal dilatation: a case report
BACKGROUND The original 'candy-plug' technique has been reported to be beneficial for the treatment of residual perfused false lumen in patients with aortic dissection. However, this technique is also associated with several problems, such as narrowing of the true lumen and damage to the flap or vessel wall. Therefore, we modified the procedure to overcome these problems. Here we report a case ...
متن کاملMid-term results of aortoplasty for dilated ascending aorta associated with aortic valve disease.
BACKGROUND Dilatation of the ascending aorta concomitant with aortic valve disease is occasionally associated with progressive enlargement of the ascending aorta or acute aortic dissection (AAD). However, surgical procedure of choice for the aorta and its indication are controversial. PATIENTS AND METHODS From July 1995 to August 2001, 10 patients with a moderately dilated ascending aorta (me...
متن کاملPseudoaneurysm of the ascending aorta after aortic valve replacement that presented as a pulsatile chest wall mass.
We describe the case of a man incidentally found to have a pseudoaneurysm of the ascending aorta at the site of a previously (12 years ago) implanted metallic prosthetic aortic valve. Transthoracic echocardiography and computed tomography images demonstrate the pseudoaneurysm. The patient has undergone surgical repair with a good result.
متن کامل[Pseudoaneurysm of the ascending aorta due to coronary anastomosis leaks].
118 In October 1993, a 67-year-old patient with hypertension underwent emergency surgery for Type A aortic dissection with cardiac tamponade. The dissection extended to both coronary arteries and was associated with annuloaortic ectasia with severe aortic regurgitation. The intervention consisted of aortic valve replacement with a 25-mm Carbomedics metal prosthetic valve (Figure 1, a), complete...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 83 3 شماره
صفحات -
تاریخ انتشار 2007