Use of reactance to estimate transpulmonary resistance.
نویسندگان
چکیده
This study examines the relationship of respiratory system resistance (R(rs)) and reactance (X(rs)) measured by forced oscillometry with transpulmonary resistance (R(L)) measured by oesophageal manometry. Simultaneous forced oscillometry using a single frequency of 5 Hz and oesophageal manometry were performed on five asthmatics during bronchoprovocation. The data obtained were used to derive prediction equations for R(L) from oscillometric parameters, which were tested on a further six asthmatics and 35 nonasthmatic subjects. In the first five asthmatic subjects, R(L) correlated more strongly with X(rs) than with R(rs). In the second set of asthmatics, R(L) ranged 0.0005-4.57 kPa.s.L(-1), with a median of 0.21 kPa.s.L(-1). The R(L) values predicted from X(rs) showed a mean+/-sd difference of -0.067+/-0.25 kPa.s.L(-1) compared with the values measured in this set of patients. X(rs) in subjects with other respiratory conditions appeared to follow the same relationship with R(L) as in asthmatics. Lumped element modelling suggested that the linear relationship between X(rs) and R(L) was a consequence of the increasing contribution of central and upper airway wall shunts as peripheral airway resistance rose, and that this effect was much larger than that due to changes in static elastance. In conclusion, the reactance of the respiratory system can predict transpulmonary resistance more accurately than can the resistance of the respiratory system.
منابع مشابه
Analytic assessment of the various bioimpedance methods used to estimate body water.
Knowledge of patient fluid distribution would be useful clinically. Both single-frequency (SF) and impedance modeling approaches are proposed. The high intercorrelation between body water compartments makes determining the best approach difficult. This study was conducted to evaluate the merits of an SF approach. Mathematical simulation was performed to determine the effect of tissue change on ...
متن کاملA Fast Method for Calculation of Transformers Leakage Reactance Using Energy Technique
Energy technique procedure for computing the leakage reactance in transformers is presented. This method is very efficient compared with the use of flux element and image technique and is also remarkably accurate. Examples of calculated leakage inductances and the short circuit impedance are given for illustration. For validation, the results are compared with the results obtained using practic...
متن کاملA comparison of inhaled nitric oxide with intravenous vasodilators in the assessment of pulmonary haemodynamics prior to cardiac transplantation.
OBJECTIVE Elevated pulmonary vascular resistance and transpulmonary gradient are predictors of increased perioperative mortality in patients undergoing orthotopic heart transplantation. Sodium nitroprusside and prostacyclin PGI2 are routinely used to assess the reversibility of pulmonary vascular resistance and transpulmonary gradient in heart transplant candidates, but their use is limited by ...
متن کاملPhase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis
Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...
متن کاملThe effect of subcutaneous fat on electrical impedance myography when using a handheld electrode array: the case for measuring reactance.
OBJECTIVE Recent developments in electrical impedance myography (EIM) have led to the use of handheld electrode arrays (HEAs) for data acquisition. Although preferable for several reasons, this approach tends to be more affected by subcutaneous fat (SF) than the original approach in which the impedance-measuring electrodes are widely spaced. In this study, we seek to identify the EIM parameter ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 25 6 شماره
صفحات -
تاریخ انتشار 2005