Quantification of cellular acid sphingomyelinase and galactocerebroside beta-galactosidase activities by electrospray ionization mass spectrometry.

نویسندگان

  • X Zhou
  • F Turecek
  • C R Scott
  • M H Gelb
چکیده

BACKGROUND Diagnosis of Niemann-Pick (A and B) and Krabbe diseases is achieved by measurement of the lysosomal enzymes acid sphingomyelinase (ASM) and galactocerebroside beta-galactosidase (GCG), respectively. Conventional assays use radiolabeled or fluorescent substrates and do not allow simultaneous determination of two or more enzymes in the sample. METHODS We developed a sensitive and specific method to assay ASM and GCG in skin fibroblast homogenates using biotinylated substrate conjugates. The products were purified by bioaffinity capture on streptavidin-agarose beads and, following release, were analyzed by electrospray ionization mass spectrometry. Quantification was achieved using stable-isotope-labeled internal standards that were chemically identical to the products of the enzymatic reactions. RESULTS The method demonstrated excellent linearity of ASM and GCG enzymatic product formation with the amount of cellular protein and incubation time. The range of ASM activities in fibroblast lysates from six healthy patients was 39-70 nmol. mg(-1). h(-1) compared with 3.7-5.1 nmol. mg(-1). h(-1) in cell lysates from two patients affected with Niemann-Pick A disease. The GCG activities toward the corresponding substrate conjugate were 4.0-6.8 nmol. mg(-1). h(-1) in cell lysates from healthy patients compared with 0.1-0.2 nmol. mg(-1). h(-1) in cell lysates from two patients affected with Krabbe disease. The amounts of substrate conjugates needed per analysis were 15 nmol (14 microg) for both ASM and GCG. CONCLUSIONS Electrospray mass spectrometry combined with the use of biotinylated substrate conjugates and bioaffinity purification represents a new approach for the diagnosis of lysosomal storage diseases as demonstrated for Niemann-Pick A and Krabbe diseases. No radioactive substrates are used, and the method uses a single instrumental platform to determine both ASM and GCG in one cell sample.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2001