Balanced SSFP-like steady-state imaging using small-tip fast recovery with a spectral prewinding pulse.

نویسندگان

  • Hao Sun
  • Jeffrey A Fessler
  • Douglas C Noll
  • Jon-Fredrik Nielsen
چکیده

PURPOSE Small-tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady-state free precession (bSSFP). STFR relies on a tailored "tip-up" radio-frequency pulse to achieve comparable signal level as bSSFP, but with reduced banding artifacts and transient oscillations, and is compatible with magnetization-preparation pulses. Previous STFR implementations used two-dimensional or three-dimensional pulses spatially tailored to the accumulated phase calculated from a B0 field map, making the steady-state STFR signal contain some T2* weighting. Here, we propose to replace the spatially tailored pulse with a recently introduced spectrally selective "pre-winding" pulse that is precomputed to a target frequency range. The proposed "spectral-STFR" sequence produces T2/T1-weighted images similar to bSSFP, but with reduced banding and potentially other benefits. THEORY AND METHODS We investigated the steady-state signal properties of spectral-STFR using simulations, and phantom and human volunteer experiments. RESULTS Our simulation and experimental results showed that the spectral-STFR sequence has similar signal level and tissue contrast as bSSFP, but has a wider passband and more consistent banding profiles across different tissues (e.g., less hyperintense signal at band edges for low flip angles). Care is needed in designing the spectral radio-frequency pulse to ensure that the small tip angle approximation holds during radio-frequency transmission. CONCLUSION Spectral-STFR has similar tissue contrast as bSSFP but a wider passband and more consistent cerebrospinal fluid/brain tissue contrast across the passband. The spectral-STFR sequence is a potential alternative to bSSFP in some applications. Compared to a spatially tailored STFR sequence, spectral-STFR can be precomputed, is easier to implement in practice, and potentially has more uniform image contrast and minimal T2* weighting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small-tip Fast Recovery (STFR) imaging Using Spectrally Tailored Pulse

Introduction: Small tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady state free precession (bSSFP) [1, 2]. STFR relies on a tailored “tip-up” RF pulse (Fig. 1(a)) to achieve comparable signal level and image contrast as bSSFP, but with reduced banding artifacts. Previous STFR implementations used 2D or 3D pulses spatially tailored to the ...

متن کامل

Small-tip fast recovery imaging using non-slice-selective tailored tip-up pulses and radiofrequency-spoiling.

Small-tip fast recovery (STFR) imaging is a new steady-state imaging sequence that is a potential alternative to balanced steady-state free precession. Under ideal imaging conditions, STFR may provide comparable signal-to-noise ratio and image contrast as balanced steady-state free precession, but without signal variations due to resonance offset. STFR relies on a tailored "tip-up," or "fast re...

متن کامل

Strategies for Improved 3D Small-Tip Fast Recovery (STFR) Imaging

Introduction: Small tip fast recovery (STFR) imaging has been proposed recently as a potential alternative to balanced steady state free precession (bSSFP). STFR relies on a tailored “tip-up” RF pulse (Fig. 1(a)) to achieve comparable signal level and image contrast as bSSFP, but with reduced banding artifacts [1]. 2D STFR imaging can use fast 2D tailored pulses (e.g., spiral) in combination wi...

متن کامل

Ultrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast

INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...

متن کامل

Breast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE

INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 75 2  شماره 

صفحات  -

تاریخ انتشار 2016