Determination of loss of consciousness: a comparison of clinical assessment, bispectral index and electroencephalogram: An observational study.
نویسندگان
چکیده
BACKGROUND Computer-processed algorithms of encephalographic signals are widely used to assess the depth of anaesthesia. However, data indicate that the bispectral index (BIS), a processed electroencephalography monitoring system, may not be reliable for assessing the depth of anaesthesia. OBJECTIVE The aim of this study was to evaluate the ability of the BIS monitoring system to assess changes in the level of unconsciousness, specifically during the transition from consciousness to unconsciousness, in patients undergoing total intravenous anaesthesia with propofol. We compared BIS with the electroencephalogram (EEG), and clinical loss of consciousness (LOC) defined as loss of verbal commands and eyelash reflex. DESIGN This was an observational cohort study. SETTING University Hospital Linköping, University Hospital Örebro, Finspång Hospital and Kalmar Hospital, Sweden from October 2011 to April 2013. PATIENTS A total of 35 ASA I patients aged 18 to 49 years were recruited. INTERVENTIONS The patients underwent total intravenous anaesthesia with propofol and remifentanil for elective day-case surgery. Changes in clinical levels of consciousness were assessed by BIS and compared with assessment of stage 3 neurophysiological activity using the EEG. The plasma concentrations of propofol were measured at clinical LOC and 20 and 30 min after LOC. MAIN OUTCOME MEASURES The primary outcome was measurement of BIS, EEG and clinical LOC. RESULTS The median BIS value at clinical LOC was 38 (IQR 30 to 43), and the BIS values varied greatly between patients. There was no correlation between BIS values and EEG stages at clinical LOC (r = -0.1, P = 0.064). Propofol concentration reached a steady state within 20 min. CONCLUSION There was no statistically significant correlation between BIS and EEG at clinical LOC. BIS monitoring may not be a reliable method for determining LOC. CLINICAL TRIALS REGISTRY This trial was not registered because registration was not mandatory at the time of the trial.
منابع مشابه
Monitoring Depth of Anesthesia by Nonlinear Correlation Measures
Background: Monitoring the depth of anesthesia (DOA) takes an important role for anesthetists in order avoiding undesirable reactions such as intraoperative awareness, prolonged recovery and increased risk of postoperative complications.The Central Nervous System (CNS) is the main target of anesthetic drugs, hence EEG signal processing during anesthesia is helpful for monitoring DOA. In order t...
متن کاملMonitoring depth of anesthesia utilizing a combination of electroencephalographic and standard measures.
BACKGROUND For decades, monitoring depth of anesthesia was mainly based on unspecific effects of anesthetics, for example, blood pressure, heart rate, or drug concentrations. Today, electroencephalogram-based monitors promise a more specific assessment of the brain function. To date, most approaches were focused on a "head-to-head" comparison of either electroencephalogram- or standard paramete...
متن کاملتاثیر سن بالا بر روی شاخص دو طیفی (Bispectral Index) قبل و بعد از تزریق آرامبخش: یک مطالعه آیندهنگر
Background: The Bispectral Index (BIS) is an EEG-derived value that measures the sedative and hypnotic component of the anesthetic state. The effects of age on the bispectral index have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and bispectral index in awake and in patients with sedation induced by midazolam.Methods...
متن کاملImpact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery
Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...
متن کاملBispectral index decreased to "0" in propofol anesthesia after a cross-clamping of descending thoracic aorta.
THE Bispectral Index (BIS) monitor (BIS® monitor; Aspect Medical System, Inc., Newton, MA) integrates electroencephalographic data via a proprietary algorithm based on empirical data into a nominal 100 to 0 scale, in which 100 represents the awake state and 0 represents the isoelectric electroencephalogram. The BIS® monitor is highly capable of correctly predicting both the loss and recovery of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of anaesthesiology
دوره 33 12 شماره
صفحات -
تاریخ انتشار 2016