Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning

نویسنده

  • Malou Hultcrantz
چکیده

OBJECTIVE To longitudinally follow the osseointegration using Resonance Frequency Analysis (RFA) for different lengths of abutment on a new wide bone-anchored implant, introduced with the non-skin thinning surgical technique. STUDY DESIGN A single-center, prospective 1 year study following adults with bone-anchored hearing implants. MATERIALS AND METHODS Implantation was performed and followed for a minimum of 1 year. All patients were operated on according to the tissue preserving technique. A 4.5 mm wide fixture (Oticon Medical) with varying abutments (9 to 12 mm) was used and RFA was tested 1 week, 7 weeks, 6 months, and 12 months later. Implant Stability Quotient (ISQ), was measured from 1 to 100. Stability was compared to a group of patients (N = 7) implanted with another brand (Cochlear BI400) of 4.5 mm fixtures. RESULTS All 10 adults concluded the study. None of the participants lost their implant during the test period indicating a good anchoring of abutments to the wide fixture tested. Stability testing was shown to vary depending on abutment length and time after surgery and with higher values for shorter abutments and increasing values over the first period of time. One patient changed the abutment from 12 to 9 mm and another from a 9 to a 12 during the year. No severe skin problems, numbness around the implant, or cosmetic problems arose. CONCLUSION After 1 year of follow-up, combination of a wide fixture implant and the non-skin thinning surgical technique indicates a safe procedure with good stability and no abutment losses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcome of a Wide-diameter Bone-anchored Hearing Implant and a Surgical Technique With Tissue Preservation

OBJECTIVE To investigate the clinical outcome of a surgical technique with tissue preservation for a wide bone-anchored hearing implant concerning postoperative complications, skin reactions, implant loss, and implant stability. STUDY DESIGN Consecutive, prospective case series. SETTING Tertiary referral center. PATIENTS Twenty-four adult patients with normal skin quality were enrolled. ...

متن کامل

A New Wide-Diameter Bone-Anchored Hearing Implant—Prospective 1-Year Data on Complications, Implant Stability, and Survival

OBJECTIVE To investigate a new wide bone-anchored hearing implant considering initial stability, stability over time, implant loss, and skin reaction. STUDY DESIGN Consecutive, prospective case series. SETTING Tertiary referral center. PATIENTS Twenty adult patients were enrolled. All operations were 1-stage, single-incision technique with subcutaneous reduction. INTERVENTION(S) Measure...

متن کامل

Surgical Excision as the First Therapeutic Choice in Single-muscle Hemangiomas: a Case Series

Background: Conservative management is generally the primary treatment for intramuscular hemangimas. However,many patients will require surgery later in their life, after suffering a long period of pain. We aimed to evaluate theoncologic and functional outcomes of surgery as the initial treatment of single-muscle hemangiomas.Methods: Medical profiles of 17 patients with hemang...

متن کامل

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

متن کامل

Patient Outcomes in Magnet-Based Implantable Auditory Assist Devices.

IMPORTANCE Magnet-based implantable auditory assist devices (MIAADs) are a recent development in bone-anchored hearing devices. This report increases the number of children studied with specific outcome criteria and provides detailed solutions to avoid device use difficulties in other centers considering this device. OBJECTIVE To assess hearing thresholds, use rates, and complications in chil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015