Fast spin-echo triple-echo dixon (fTED) technique for efficient T2-weighted water and fat imaging.
نویسندگان
چکیده
Previously published fast spin-echo (FSE) implementations of a Dixon method for water and fat separation all require multiple scans and thus a relatively long scan time. Further, the minimum echo spacing (esp), a time critical for FSE image quality and scan efficiency, often needs to be increased in order to bring about the required phase shift between the water and fat signals. This work proposes and implements a novel FSE triple-echo Dixon (fTED) technique that can address these limitations. In the new technique, three raw images are acquired in a single FSE scan by replacing each frequency-encoding gradient in a conventional FSE with three consecutive gradients of alternating polarity. The timing of the three gradients is adjusted by selecting an appropriate receiver bandwidth (RBW) so that the water and fat signals for the three corresponding echoes have a relative phase shift of -180 degrees , 0 degrees , and 180 degrees , respectively. A fully automated postprocessing algorithm is then used to generate separate water-only and fat-only images for each slice. The technique was implemented with and without parallel imaging. We demonstrate that the new fTED technique enables both uniform water/fat separation and fast scanning with uncompromised scan parameters, including applications such as T(2)-weighted separate water and fat imaging of the abdomen during breath-holding.
منابع مشابه
Improving fat-suppressed T2-weighted imaging of the head and neck with 2 fast spin-echo dixon techniques: initial experiences.
Two modified fast spin-echo (FSE) techniques (a 2-point and a single-scan triple-echo Dixon) were used for T2-weighted imaging of the head and neck in 7 patients along with conventional FSE with fat saturation. Both Dixon techniques provided consistent and more uniform fat suppression (FS) than conventional FSE. The 2-point Dixon technique was noted to be more susceptible to motion artifacts. T...
متن کاملFlow Compensation in Frequency-encode Direction for the Fast Spin Echo Triple-Echo Dixon (FTED) Sequence
Figure 2: Phantom images and separated fat-only and water-only images for (a) FTED, (b) nulling at RF, (c) nulling at the echo center. Flow-artifacts are effectively reduced in (b) and (c). Note that water tube in (a) and (b) was incorrectly separated into the fat-only image because the existing region growing algorithm cannot handle disconnected objects. (c) (b) (a) Flow Compensation in Freque...
متن کاملSingle session whole body T2-weighted and T1-weighted MRI (both with and without fat suppression)
Introduction: An MRI study is commonly used for examining the local extent of a disease and often consists of acquiring images of the same region with different image contrasts. Using a moving tabletop and without re-positioning the patient, MRI has also been shown to be a feasible tool for whole body screening or staging of a disease [1-3]. In this regard, whole body MRI is potentially more ad...
متن کاملFat-suppressed MR of the orbit and cavernous sinus: comparison of fast spin-echo and conventional spin-echo.
PURPOSE To compare T2-weighted fat-suppressed fast spin-echo imaging with fat-suppressed conventional spin-echo imaging in the detection of normal intraorbital and pericavernous anatomy and orbital disease, and to determine the efficacy of fat saturation with T2-weighted fast spin-echo imaging of the cavernous sinus. METHODS Contrast-to-noise ratios of normal intraorbital anatomy were calcula...
متن کاملFat Suppressed FSE Pelvic MR Imaging with Two New FSE Based Dixon Pulse Sequences: A Comparison of IDEAL FSE and FSE Triple Echo Dixon
Background: Fat suppressed FSE T2-weighted imaging is an integral part of an MR pelvic examination. However, fat suppression by conventional technique can be degraded by inhomogeneities of the magnetic field. The problem can be exacerbated when a typical large FOV is used for abdominal and pelvic imaging. Techniques that provide fat-suppressed T2-weighted imaging that is insensitive to field in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 58 1 شماره
صفحات -
تاریخ انتشار 2007