Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®

نویسندگان

  • Tobias Helfen
  • Georg Siebenbürger
  • Marcel Mayer
  • Wolfgang Böcker
  • Ben Ockert
  • Florian Haasters
چکیده

BACKGROUND Proximal humeral fractures are with an incidence of 4-5 % the third most common fractures in the elderly. In 20 % of humeral fractures there is an indication for surgical treatment according to the modified Neer-Criteria. A secondary varus dislocation of the head fragment and cutting-out are the most common complications of angle stable locking plates in AO11-A3 fractures of the elderly. One possibility to increase the stability of the screw-bone-interface is the cement augmentation of the screw tips. A second is the use of a multiplanar angle stablentramedullary nail that might provide better biomechanical properties after fixation of 2-part-fractures. A comparison of these two treatment options augmented locking plate versus multiplanar angle stable locking nail in 2-part surgical neck fractures of the proximal humerus has not been carried out up to now. METHODS/DESIGN Forty patients (female/male, ≥60 years or female postmenopausal) with a 2-part-fracture of the proximal humerus (AO type 11-A3) will be randomized to either to augmented plate fixation group (PhilosAugment) or to multiplanar intramedullary nail group (MultiLoc). Outcome parameters are Disabilities of the Shoulder, Arm and Hand-Score (DASH) Constant Score (CS), American Shoulder and Elbow Score (ASES), Oxford Shoulder Score (OSS), Range of motion (ROM) and Short Form 36 (SF-36) after 3 weeks, 6 weeks, 3 months, 6 months, 12 and 24 months. DISCUSSION Because of the lack of clinical studies that compare cement augmented locking plates with multiplanar humeral nail systems after 2-part surgical neck fractures of the proximal humerus, the decision of surgical method currently depends only on surgeons preference. Because only a randomized clinical trial (RCT) can sufficiently answer the question if one treatment option provides advantages compared to the other method we are planning to perform a RCT. TRIAL REGISTRATION Clinical Trial ( NCT02609906 ), November 18, 2015, registered retrospectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Osteosynthesis of Proximal Humeral End Fractures with Fixed-angle Plate and Locking Screws: Technique and Results

UNLABELLED Describe the results of proximal humeral fractures surgically treated with the Philos locking plate system. METHOD Between March 2003 and October 2004 we prospectively reviewed 24 of 26 patients with proximal humerus fractures treated with a Philos plate. The mean follow-up time was 12 months and the mean age of patients was 57 years. Six patients had four-part proximal humerus fra...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Locking plates in proximal humerus fractures.

It is well known that proximal humerus fractures are among the three most frequent fracture types. Epidemiological invetsigations show that in people elder than 60 years the fracture of the proximal humerus is more frequent than fractures of the hip region (17). Over the last decades several techniques have been applied for treatment of proximal humerus fractures. Widely accepted is the initiat...

متن کامل

PHILOS Plate: Is it the Panacea for all Proximal Humerus Fractures?

Proximal humerus fractures are common and have a bimodal age distribution. Fracture-dislocations in younger patients result from highenergy trauma and most surgeons attempt open reduction and internal fixation, if at all possible. Osteoporotic fractures in elderly patients are commonly associated with low-energy trauma such as groundlevel falls and most are minimally displaced, impacted fractur...

متن کامل

Long Term Results of PHILOS Plating and Percutaneous K-Wire Fixation in Proximal Humerus Fractures in The Elderly

ABSTRACT This is a report of a study on the long term results of PHILOS plating and percutaneous K-wire fixation in a prospective series of proximal humerus fractures in elderly patients. We reviewed a total of 60 patients with proximal humerus fractures in 30 patients (Group 1), who were treated by open reduction and internal fixation with Proximal Humeral Internal Locking System (PHILOS) plat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016