Preclinical evaluation of acoustic radiation force impulse measurements in regions of heterogeneous elasticity

نویسندگان

  • Katharina Hollerieth
  • Bernhard Gaßmann
  • Stefan Wagenpfeil
  • Philipp Moog
  • Minh-Truc Vo-Cong
  • Uwe Heemann
  • Konrad Friedrich Stock
چکیده

PURPOSE The purpose of this study was to compare the reliability of ultrasound-based shear wave elastography in regions of homogeneous versus heterogeneous elasticity by using two different probes. METHODS Using acoustic radiation force impulse (ARFI) elastography, we measured the shear wave velocity (SWV) in different lesions of an elastography phantom with the convex 4C1 probe and the linear 9L4 probe. The region of interest (ROI) was positioned in such a way that it was partly filled by one of the lesions (0%, 25%, 50%, 75%, and 100%) and partly by the background of the phantom (100%, 75%, 50%, 25%, and 0%, respectively). RESULTS The success rate was 98.5%. The measured value and the reference value of SWV correlated significantly (r=0.89, P<0.001). Further, a comparison of the two probes revealed that there was no statistical difference in either the mean or the variance values. However, the deviation of SWV from the reference was higher in the case of the 9L4 probe than in the case of the 4C1 probe, both overall and in measurements in which the ROI contained structures of different elasticity (P=0.021 and P=0.002). Taking into account all data, for both probes, we found that there was a greater spread and deviation of the SWV from the reference value when the ROI was positioned in structures having different elastic properties (standard deviation, 0.02±0.01 m/sec vs. 0.04±0.04 m/sec; P=0.010; deviation from the reference value, 0.21±0.12 m/sec vs. 0.38±0.27 m/sec; P=0.050). CONCLUSION Quantitative ARFI elastography was achievable in structures of different elasticity; however, the validity and the reliability of the SWV measurements decreased in comparison to those of the measurements performed in structures of homogeneous elasticity. Therefore, a convex probe is preferred for examining heterogeneous structures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Testicular microlithiasis and preliminary experience of acoustic radiation force impulse imaging

BACKGROUND Elastography of the testis can be used as a part of multiparametric examination of the scrotum. PURPOSE To determine the testicular stiffness using acoustic radiation force impulse imaging (ARFI) technique in men with testicular microlithiasis (TML). MATERIAL AND METHODS In 2013, 12 patients with diagnosed testicular microlithiasis in 2008 (mean age, 51 years; age range, 25-76 ye...

متن کامل

Evaluation of Acoustic Radiation Force Impulse Imaging (ARFI) for the Determination of Liver Stiffness Using Transient Elastography as a Reference in Children.

PURPOSE Transient elastography (Fibroscan(©); (FS)) and acoustic radiation force impulse imaging (ARFI) represent noninvasive, user-friendly and quick methods providing an objective and reproducible measure of liver stiffness. The aim of the study was to evaluate cut-off values and performance of ARFI measurements in children using transient elastography as a reference. METHODS/PATIENTS A tot...

متن کامل

Improving Displacement Signal-to-Noise Ratio for Low-Signal Radiation Force Elasticity Imaging Using Bayesian Techniques.

Radiation force-based elasticity imaging is currently being investigated as a possible diagnostic modality for a number of clinical tasks, including liver fibrosis staging and the characterization of cardiovascular tissue. In this study, we evaluate the relationship between peak displacement magnitude and image quality and propose using a Bayesian estimator to overcome the challenge of obtainin...

متن کامل

Acoustic Radiation Force Impulse Is Equivalent to Liver Biopsy to Evaluate Liver Fibrosis in Patients with Chronic Hepatitis C and Nonalcoholic Fatty Liver Disease.

BACKGROUND Liver biopsy is recommended as the gold standard method for assessing the stage of liver fibrosis in patients with chronic liver disease. However, it is invasive, with potential risks and complications. Elastography is an ultrasound technique that provides information of changes in the liver tissue, evaluating tissue elasticity and acoustic radiation force impulse is one of the avail...

متن کامل

Does standoff material affect acoustic radiation force impulse elastography? A preclinical study of a modified elastography phantom

PURPOSE This study was conducted to determine the influence of standoff material on acoustic radiation force impulse (ARFI) measurements in an elasticity phantom by using two different probes. METHODS Using ARFI elastography, 10 observers measured the shear wave velocity (SWV, m/sec) in different lesions of an elasticity phantom with a convex 4C1 probe and a linear 9L4 probe. The experimental...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 35  شماره 

صفحات  -

تاریخ انتشار 2016