Thrombomodulin-modified thrombin generation after in vivo recombinant factor VIII treatment in severe hemophilia A.
نویسندگان
چکیده
BACKGROUND Thrombin generation has been shown to reflect coagulation potential and factor VIII (FVIII) levels in patients with hemophilia A. We hypothesize that thrombin generation in the presence of thrombomodulin reflects plasma FVIII levels better. DESIGN AND METHODS Plasma FVIII levels were determined chromogenically and thrombin generation was measured with and without thrombomodulin in 12 patients with severe hemophilia A. Blood was sampled at baseline and 15 min, 1, 3, 6, 24 and 48 hours after recombinant FVIII administration. RESULTS FVIII administration restored the decreased baseline thrombin generation (reflected by endogenous thrombin potential, peak height, slope and time to peak). Lag time did not change. All thrombin generation parameters except time to peak returned to baseline within 48 hours, while plasma FVIII concentration was increased and time to peak shortened. Endogenous thrombin potential and peak height showed wide inter-individual variation, with strong intra-individual correlations. Addition of thrombomodulin to the assay shortened time to peak and decreased endogenous thrombin potential and peak height. The decrease in peak height was almost completely offset by FVIII administration. Multiple linear regression analysis revealed thrombomodulin-modified thrombin generation to be a moderately better predictor of plasma FVIII levels than thrombin generation in the absence of thrombomodulin (adjusted R(2) 0.79 vs. 0.71). CONCLUSIONS Addition of thrombomodulin has pronounced effects on all parameters of thrombin generation. This thrombomodulin-modified thrombin generation assay better reflects plasma FVIII levels than thrombin generation in the absence of thrombomodulin.
منابع مشابه
A prospective Crossover Triple-blind Controlled Trial on the Safety and Efficacy of Iranian Recombinant FVIII (Safacto) versus Plasma Derived FVIII A pilot study
Background: Considering the increasing number of patients with hemophilia and infrastructure requirements for a comprehensive approach, development of a recombinant factor has become a milestone. The objective of this study was to assess the safety, efficacy and non inferiority of Safacto (Recombinant factor VIII) compared with plasma-derived factor in the treatment of hemophilia A. Methods: 10 ...
متن کاملAn in vitro analysis of the combination of hemophilia A and factor V(LEIDEN).
The classification of factor VIII deficiency, generally used based on plasma levels of factor VIII, consists of severe (<1% normal factor VIII activity), moderate (1% to 4% factor VIII activity), or mild (5% to 25% factor VIII activity). A recent communication described four individuals bearing identical factor VIII mutations. This resulted in a severe bleeding disorder in two patients who carr...
متن کاملSolulin increases clot stability in whole blood from humans and dogs with hemophilia.
Solulin is a soluble form of thrombomodulin that is resistant to proteolysis and oxidation. It has been shown to increase the clot lysis time in factor VIII (fVIII)-deficient plasma by an activated thrombin-activatable fibrinolysis inhibitor (TAFIa)-dependent mechanism. In the present study, blood was drawn from humans and dogs with hemophilia, and thromboelastography was used to measure tissue...
متن کاملDetection of Factor VIII Inhibitors in Hemophilia A Patients
Background: Factor VIII administration to hemophilia A patients results in an immune response (inhibitor formation) which significantly complicates the therapy. The present study was performed to determine the prevalence of inhibitor development in hemophilia A patients receiving recombinant factor VIII therapy. Materials and Methods: This was an observational descriptive study. Clotting fac...
متن کاملDeterminants of plasma factor VIIa levels in humans.
Several enzymes can activate factor VII in vitro, but the protease responsible for generating factor VIIa in vivo has not been determined. Using recombinant tissue factor that has undergone a COOH-terminal truncation, a sensitive functional assay has been established for measuring plasma factor VIIa levels. To evaluate the mechanism responsible for the generation of factor VIIa in vivo, we meas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Haematologica
دوره 93 9 شماره
صفحات -
تاریخ انتشار 2008