Development of a Selective Post-column Detector for Phenols Separated by High-performance Liquid Chromatography
نویسنده
چکیده
An on-line post-column reactor based on air-segmented continuous flow is described for the determination of phenols. The reaction used is the coupling of diazotized sulfanilic acid with phenols to form highly colored azo dyes. The effect of experimental parameters on the detector response was investigated by both univariate and simplex approaches in order to establish optimum reaction conditions. The aqueous reaction system is compatible with common reverse-phase solvents. The detection limit for phenol with the derivatization detector (71 Irg 1-l) shows a Is-fold improvement over U.V. detection of the underivatized phenol. Imprecision, based on multiple injections of sample into the HPLC system and measurement of the peak heights, is *0.64% (RSD). The technique is applied to the determination of phenols added to river water and present in residual fuel oil samples.
منابع مشابه
Determination of Aflatoxins B1 and B2 in Powdered Milk Using Modified Liquid Chromatography Method
Background & Aims: In this study, using a liquid-liquid microextraction method for pre-concentration trace amounts of aflatoxins, the amount of Aflatoxins B1 and B2 in powdered milk was determined. Determination of aflatoxins was done by using high-performance liquid chromatography coupled with fluorescent detector. Method: Samples were extracted by immunoaffinity column (IAC) clean-up, and the...
متن کاملDetermination of some B Vitamins in Sour Cherry Juice Using Dispersive Liquid-liquid Microextraction Followed by High-performance Liquid Chromatography
Dispersive liquid-liquid microextraction method (DLLME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) was used to determine thiamine (B1), nicotinamide (B3) and pyridoxine (B6) in sour cherry juice. This method was rapid, simple and sensitive. Separation was accomplished using a C18 column. The optimum chromatographic conditions were found to be: mobile ph...
متن کاملDetermination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملLiquid chromatography with post-column electrochemical treatment and mass spectrometric detection of non-polar compounds.
The first hyphenation of high performance liquid chromatography (HPLC), electrochemical online oxidation and mass spectrometry (MS) is described. Ferrocenecarboxylic acid esters of various alcohols and phenols have been synthesized, separated by reversed-phase HPLC and oxidized (ionized) coulometrically prior to single quadrupole MS analysis using electrospray ionization (ESI) and atmospheric p...
متن کامل