The accuracy of two different extra-medullary tibial cutting guides for posterior tibial slope in total knee arthroplasty.
نویسندگان
چکیده
OBJECTIVES This study aims to evaluate the effectiveness of two different external tibial cutting guides with and without a spike anchoring to the intercondylar eminentia to achieve a desired posterior tibial slope. PATIENTS AND METHODS Between January 2008 and December 2011, 120 posterior cruciate ligament protecting total knee arthroplasty (TKA) surgeries of 83 patients in which two different external tibial cutting guides used were included. Fifty-nine knees were included into the spiked and 61 knees were included into the spikeless cutting guide group. Posterior tibial slope angles were measured using the postoperative X-rays. RESULTS There was no significant difference between two groups in terms of age, sex, and body mass indexes (p<0.05). While the mean postoperative slope angle was 2.66°±2.001°(range 0°-7°) in spiked group, it was 2.46°±2.277° (range 0°-7°) in spikeless group. Both systems had identical accuracy, indicating a low rate. The comparison of variances of two groups showed that both cutting guides had similar precision (p=0.234). There was no effect of body mass index on the results in both groups. CONCLUSION Although different extra-medullary tibial cutting guides with and without a spike can reproducibly impart a desired posterior tibial slope in TKA, we concluded that a spiked guide was considered user-friendly.
منابع مشابه
Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging
Background: Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which leads to knee joint stability. Posterior tibial slope affects flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the...
متن کاملComponent position alignment with patient-specific jigs in total knee arthroplasty.
BACKGROUND The failure to restore mechanical alignment and appropriate rotational axis intraoperatively has been described as one of the most common causes of implant failure in total knee arthroplasty (TKA). Both conventional and computer-assisted TKA have their limitations. Patient-specific jigs (PSJ) offer a possible alternative method for TKA. The aim of this study was to investigate if the...
متن کاملThe effect of implant position on bone strain following lateral unicompartmental knee arthroplasty
OBJECTIVES Unicompartmental knee arthroplasty (UKA) is a demanding procedure, with tibial component subsidence or pain from high tibial strain being potential causes of revision. The optimal position in terms of load transfer has not been documented for lateral UKA. Our aim was to determine the effect of tibial component position on proximal tibial strain. METHODS A total of 16 composite tibi...
متن کاملExtramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement
BACKGROUND In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. METHODS A compara...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2014